background image

5

SimpliFire  •  SF-ALLP50-BK, SF-ALLP60-BK, SF-ALLP72-BK  •  2044-980  Rev. C  •  10/19

    

Note:

  The device complies with Part 15 of the FCC Rules.  

Operation is subject to the following two conditions:
1.  This device may not cause harmful Electromagnetic  

      Interference (EMI), and
2.  This device must  accept any interference received,  

    including interference that may cause undesired  

      operation.

MODELS:

 SF-ALLP50-BK, SF-ALLP60-BK, SF-ALLP72-BK 

 

 

LABORATORY:  

CSA International

TYPE:  

Electric Air-Heaters; Fixed and Location-Dedicated 

 

             Electric Room Heaters

STANDARD:

 CSA C22.2 No 46-2013; UL 2021 (4

nd

 Edition)

A.  Appliance Certification

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance.  It should not be 

factored as primary heat in residential heating calculations.

NOTICE: 

This installation must conform with local building 

electrical codes. 

GENERAL INFORMATION 

  

B.  Unpacking and Inspecting Appliance 

WARNING!  DO NOT use this Electric Fireplace if

  any 

part has been under water.  

Immediately  call  a  qualified 

service technician to inspect and to replace any part of the 

electrical system if necessary.  Keep plastic wrapping away 

from children.

•  Carefully remove the appliance and components from the 

packaging.  Discard packaging.

•  Carefully inspect components for any damage.
•  Reference parts list to verify all parts have been received.
•  Read all the instructions before starting the installation.  

Follow these instructions carefully during the installation to 

ensure maximum safety and benefit.

This equipment uses and can radiate radio frequency 

energy and, if not installed and used in accordance 

with the instructions, may cause harmful EMI to radio or 

television reception, which can be determined by turning 

the equipment off and on.  The user is encouraged to 

try to correct the EMI by one or more of the following 

measures: 
•  Increase the separation between the equipment and the 

receiver.

•  Connect the equipment into an outlet on a circuit different 

from that to which the receiver is connected.

C.  Model and Serial Number Information 

 

The model and serial number information is located on the 

rating plate.  The rating plate is located on the bottom left of 

the appliance front, behind the glass. 

Model Name: ___________________________________________ Date purchased/installed: __________________

Serial Number: __________________________________________

Location on fireplace:

 _____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

We recommend that you record the following pertinent 

information about your fireplace.

Homeowner Reference Information

ELECTRIC FIREPLACE

MODEL                   SF-ALLPXX-BK

VOLTAGE

FREQUENCY

AMPERAGE

WATTS

SERIAL No.:

MADE IN CHINA

600165

120V AC

60 Hz

12.5  A

1500 W

WARNING:  

This product can expose you to Di-

(2-ethylhexyl) phthalate, which is known to the 

State of California to cause cancer and reproductive 

harm.  For more information go to: www.P65Warnings.

ca.gov.

Содержание SF-ALLP50-BK

Страница 1: ...P72 BK READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THIS PRODUCT PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE Please contact your SimpliFire dealer with any questions or concerns For the location of your nearest SimpliFire dealer please visit www hearthnhome com...

Страница 2: ...t malfunctions Disconnect power at service panel and have appliance inspected by a certified electrician before reusing Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the appliance To prevent a possible fire do not block appliance connection fan air intakes or exhaust in any manner A heater has hot and sparki...

Страница 3: ...10 C Electrical Connection Installation 11 D Appliance Final Setup 12 5 OPERATING INSTRUCTIONS A Manual Switch Function 13 B Operating by Remote Control 14 C Room Temperature and Thermostat Function 15 D Resetting Temperature Cutoff Switch 15 6 MAINTENANCE A Maintenance 16 B Cleaning 16 C Servicing 16 D Service Parts List 17 E Contact Information 20 Safety Alert Key DANGER Indicates a hazardous si...

Страница 4: ...es melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes Repair or replacement of parts that are subject to normal wear and tear during the warranty period These parts include paint batteries and the discoloration of glass Damages resulting from 1 failure to install operate or maintain the appliance in accordance with the inst...

Страница 5: ...n Follow these instructions carefully during the installation to ensure maximum safety and benefit This equipment uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful EMI to radio or television reception which can be determined by turning the equipment off and on The user is encouraged to try to correct the EMI by one or mo...

Страница 6: ...r for power cord installation only Type NM B Wire Strain Relief B Tools and Supplies Needed Parts and Hardware List Part Quantity Appliance 1 Glass Panel 1 Instruction Manual 1 Remote Control 1 AAA Battery 2 Trim Shipped attached to appliance with ST4X8 x14 screws SF ALLP50 BK or x18 SF ALLP60 BK SF ALLP 72 BK 1 ST4X8 screw glass to appliance 2 Side Panel 2 ST4X40 Screws appliance to framing 4 Sma...

Страница 7: ...ALLP50 BK in 52 5 16 20 7 16 48 15 50 1 2 19 3 8 5 5 8 mm 1329 519 1219 381 1283 492 143 SF ALLP60 BK in 62 5 16 20 7 16 58 15 60 1 2 19 3 8 5 5 8 mm 1583 519 1473 381 1537 492 143 SF ALLP72 BK in 74 5 16 20 7 16 70 15 72 1 2 19 3 8 5 5 8 mm 1888 519 1778 381 1842 492 143 D F G E B A C C Appliance Dimensions Including Front Trim ...

Страница 8: ... E Clearance to Combustibles Minimum Clearance to Combustible Construction Sides 0 in Floor 0 in Top 0 in Back 0 in Front 36 in Mantel 5 8 in See Figure 3 2 F Electrical Supply Circuit Requirements Plan the location of the appliance so that it will have ad equate electric power A 15 AMP 120VAC 60Hz circuit is required Additional appliances on the same circuit as this appliance may exceed the curre...

Страница 9: ... of the home to prevent cold air drafting prob lems The chase should not break the outside building envelope in any manner Walls ceiling baseplate and cantilever floor of the chase should be insulated Va por and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home Additionally in regions where cold air infiltration may be an issue the inside sur...

Страница 10: ...e is to be installed directly to the face of the wall refer to Section 4 C for installation B Recessed in 2 x 6 Framed Wall 1 Finish wall construction per requirements in Figure 4 1 Note This appliance is inteded for use with no more than 1 inch combined thickness of wallboard and finishing materials 2 Connect to electrical service Reference Section 4 D 3 Remove interior side panels on left and ri...

Страница 11: ...cted and grounded in accordance with local building elec trical codes 1 Remove terminal block cover plate located on the right end of the appliance 2 Install a wire strain relief bushing into the cover plate 3 Terminate type NM B wire to the terminal block ensure connections are secure and tighten the strain relief Use 3 32 slotted heat screwdriver or equivalent to depress the spring loaded termin...

Страница 12: ...the bottom edge into the channel behind the outer trim See Figure 4 12 Figure 4 12 Glass Front Installation CAUTION Two adults are recommended for the installation of glass front Use caution when handling glass Failure to do so could result in personal injury or property damage Note If optional logs are purchased arrange the logs on top of the crystal stones as desired ST4X8 SCREWS GLASS BRACKET C...

Страница 13: ...ns Once the unit has been properly connected to a grounded electrical outlet turn on the power button located on the lower right side of the appliance A beep should be heard when the power is first applied See Figure 5 1 Power Button The Power button turns the power of the appliance on or off Flame Button By pressing the FLAME button the unit will cycle through four flame effects Heater Button The...

Страница 14: ...ater button once heater turns on LOW Press Heater button twice heater turns on HIGH Press Heater button three times heater turns off LCD illuminates and displays heater status icon Fireplace emits single audible beep to confirm command to transition between HEATER states Fireplace displays one red LED for 10 seconds to confirm low heater command Fireplace displays two red LED for ten 10 seconds to...

Страница 15: ...to set the desired room temperature The heater will only operate if the remote control tem perature set point is higher than the actual room tempera ture The heater will not operate if the actual temperature is greater than the remote control temperature set point To exit Thermostat mode toggle Temperature button until no temperature is displayed This function can also be used as a thermostat unde...

Страница 16: ... not require further lubrication WARNING Risk of Fire To reduce risk of fire do not store or use gasoline or any other flammable vapors or liquids in the vicinity of the appliance WARNING Risk of Electrical Shock Any other servic ing needed must be performed by an authorized service representative Do not attempt to service the unit your self B Cleaning Cleaning Glass Dust particles can be removed ...

Страница 17: ...MMENTS PART NUMBER 1 Crystal Media CRYSTAL ALLUS Y 2 Rotisserie 50 ROTISS ALLP50 Y 3 Remote Receiver RECEIV ALLUS E Y 4 Flame Motor MOTOR ALLP Y 5 Fan Heater HEATER ALLP Y 6 Glass Front 50 GLA ALLP50 Y 7 Trim 50 TRIM ALLP50 Y 8 Remote REMOT ELECT ALL Y 9 Main PCB PCB ALLP Y 10 Power Cord PLUGIN ALLP Y 11 LED Assembly 50 Ember and Flame Bed Included LED ALLP50 Y 12 Button Assembly TOUCH ALLP Y 13 S...

Страница 18: ...CRIPTION COMMENTS PART NUMBER 1 Crystal Media CRYSTAL ALLUS Y 2 Rotisserie 60 ROTISS ALLP60 Y 3 Remote Receiver RECEIV ALLUS E Y 4 Flame Motor MOTOR ALLP Y 5 Fan Heater HEATER ALLP Y 6 Glass Front 60 GLA ALLP60 Y 7 Trim 60 TRIM ALLP60 Y 8 Remote REMOT ELECT ALL Y 9 Main PCB PCB ALLP Y 10 Power Cord PLUGIN ALLP Y 11 LED Assembly 60 Ember and Flame Bed Included LED ALLP60 Y 12 Button Assembly TOUCH ...

Страница 19: ...CRIPTION COMMENTS PART NUMBER 1 Crystal Media CRYSTAL ALLUS Y 2 Rotisserie 72 ROTISS ALLP72 Y 3 Remote Receiver RECEIV ALLUS E Y 4 Flame Motor MOTOR ALLP Y 5 Fan Heater HEATER ALLP Y 6 Glass Front 72 GLA ALLP72 Y 7 Trim 72 TRIM ALLP72 Y 8 Remote REMOT ELECT ALL Y 9 Main PCB PCB ALLP Y 10 Power Cord PLUGIN ALLP Y 11 LED Assembly 72 Ember and Flame Bed Included LED ALLP72 Y 12 Button Assembly TOUCH ...

Страница 20: ...___________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ Printed in China Copyright 2019 DO NOT D...

Отзывы: