VSH SUPER Compression Fittings
Technical Information
|
Installation Instructions
Remounting/multiple use of fittings
Existing connections can be removed and re-installed.
The clamp ring fixed at its intended location is placed under
tension when the union nut is tightened by hand. Then
tighten 1/8 to 1/4 turn with a spanner.
The clamp ring can be removed by making an oblique saw
cut (see Fig. 3), without damaging the pipe. Expand ring
using a flat object and carefully removed it from the pipe.
Installation information
In table 2 the insertion depths are listed for planning and
pre-fabrication (see Fig. 4).
Tables 3 and 4 show the flow resistance of the fittings at
a water velocity of 0.75 m/s expressed in the equivalent pipe
length per meter. For reduction fittings the values in table 4
are to be added to the values in table 3.
Table 2
Fitting connection
[ø mm]
Insertion depth A
[mm]
6
13.5
8
14.5
10
16.5
12
18.5
15
21.5
16
22.5
18
22.5
20
22.5
22
23.0
28
23.5
35
30.0
42
35.5
54
39
12
15
22
28
15
0.2
-
-
-
22
0.3
0.2
-
-
28
-
0.3
0.1
-
35
-
0.4
0.2
0.1
Table 4
12
15
22
28
35
42
54
0.1
0.1
0.1
0.1
0.1
0.1
0.1
-
0.5
0.6
0.7
1.2
-
-
0.5
0.5
0.8
0.8
1.2
1.4
1.8
0.1
0.1
0.2
0.2
0.2
0.2
0.2
0.5
0.5
0.8
0.8
1.2
1.4
1.8
-
0.5
0.8
0.8
1.2
-
-
-
0.1
0.1
0.2
0.2
-
-
Table 3
A
A
B
C
D
E
A
B
C
D
E
Abb. 1
Abb. 2
Abb. 3
Abb. 4
A
A
B
C
D
E
A
B
C
D
E
Abb. 1
Abb. 2
Abb. 3
Abb. 4
Fig. 3
Fig. 4
All technical data is non-binding and does not represent guaranteed properties of the goods. The illustrations are symbolic and may differ from the respective product.
Additional information is available upon request. It is the responsibility of the processor to select products in accordance with their properties. Installation instructions
must be followed. Subject to technical amendments.