background image

 

S4100-0035-6  4/2005

Audio Expansion Signal Module and Options

Model

Description 

Details and Mounting Reference 

4100-5116 

Expansion Signal Module; three, 1.5 A Class B 
NACs for Audio applications; up to five maximum 
per amplifier; NAC rating = 1.5 A, 50 W, or 100 
speakers maximum 

Converts one NAC input to three NAC outputs; selects between two 
inputs; for Flex-35/50 amplifiers only, two input NACs are required; Single 
Block module mounts in expansion bay; 

Supv = 18 mA; Alarm with 100 W 

amplifiers = 52 mA; Alarm with Flex-35/50 amplifiers = 80 mA

4100-1266 

Expansion Signal Module NAC Expander; NAC 
rating = 1.5 A, 50 W, or 100 speakers max. 

Expands module capacity to six, Class B NACs;  

Supv = 0.6 mA; Alarm = 60 mA

4100-1267 

Expansion Signal Module Class A Adapter; NAC 
rating = 1.5 A, 50 W, or 100 speakers max. 

Converts 3 Class B, NACs to Class A;

 Supv = 0.6 mA; 

Alarm = 30 mA

4100-1268 

Expansion Signal Module Constant Supervision 
Adapter;  Converts 3 Class B NACs to Constant 
Supervision Class B or Class A NACs; for 
25 VRMS or 70.7 VRMS audio 

NAC rating = 1.4 A, 50 W, or 100 speakers max.;  
Current vs operating voltage: 

25 VRMS Supv = 10 mA; 

25 VRMS Alarm = 35 mA;  70.7 VRMS Supv = 38 mA; 
70.7 VRMS Alarm = 60 mA

These
modules
mount on the 
4100-5116; 
select one
max. per 
4100-5116 
as required 

General Audio Options 

Model

Description 

4081-9018  End-of-line resistor harness for 70.7 VRMS NACs; 10 k

:

, 1 W 

4100-2320  Audio Bay-to-Bay Interconnection Harness Kit; 

order one for each audio bay addition

4100-0637  Audio Box Interconnection Harness Kit; 

order one for each close-nippled audio cabinet

Initiating Device Circuits (IDCs) 

Model

Description 

Size

Supv. 

Alarm 

4100-5005  Eight zones, Class B 

1 Slot 

75 mA 

195 mA 

4100-5015  Eight zones, Class A 

1 Slot 

75 mA 

195 mA 

Addressable Interface Modules 

Model

Description 

Size

Supv. 

Alarm 

4100-3101  IDNet Module, 250 point capacity 

With 250 IDNet devices, add 

– 

200 mA 

250 mA 

4100-3104  IDNet Module, 127 point capacity 

With 127 IDNet devices, add 

– 

102 mA 

127 mA 

4100-3105  IDNet Module, 64 point capacity 

With 64 IDNet devices, add 

– 

51 mA 

64 mA 

Module without devices 

– 

75 mA 

115 mA 

IDNet Modules, Specifications for each capacity; 

Module size = 1 Block

Loading per IDNet device  

– 

0.8 mA 

1 mA 

Model

Description 

Size

Supv. 

Alarm 

Module without devices 

– 

270 mA

290 mA

4100-3102 

MAPNET II

®

 Module, 127 point capacity, add devices separately; 

Module size = 2 Slots; Loading per MAPNET II device = 1.7 mA 

Fully loaded module, total 

– 

470 mA

490 mA

4100-3103 

Isolator Module 

for MAPNET II or IDNet 

communications; converts one SLC into four 

isolated Class A or Class B outputs; up to two Modules can be connected to one SLC; 

NOTE: 

Compatible with MAPNET II Remote Isolators only; for quad isolation with IDNet 

Remote Isolators, use 4100-3107 IDNet+ Module (refer to data sheet S4100-0046 for 
details)

1 Slot 

50 mA 

50 mA 

Relay Modules; Nonpower-Limited 

Model

Description 

Resistive Ratings 

Inductive Ratings 

Size

Supv. 

Alarm 

4100-3202  4 DPDT w/feedback 

10 A 

250 VAC 

10 A 

250 VAC 

2 Slots 

15 mA 

175 mA 

4100-3204  4 DPDT w/feedback 

2 A 

30 VDC/VAC 

1/2 A 

30 VDC/120 VAC 

1 Block 

18 mA 

70 mA 

4100-3206  8 SPDT 

3 A 

30 VDC/120 VAC 

1-1/2 A 

30 VDC/120 VAC 

1 Block 

16 mA 

200 mA 

Current Calculation Notes: 

1. 

For total supervisory current, add panel module currents to base system value 

and

 add all external loads panel-powered loads. 

2. 

For total alarm current, add panel module currents to base system alarm current 

and

 add all panel NAC loads 

and

 all external loads 

powered from panel power supplies. 

120 VAC Models 

3.5 A maximum @ 102 to 132 VAC, 60 Hz 

Input Power  

[System (SPS); Expansion (XPS); 

Remote (RPS); TrueAlert Power Supplies (TPS); 
and 100 W amplifiers] 

220-240 VAC Models 

1.75 A maximum @ 204 to 264 VAC, 50/60 Hz; 
separate taps for 220/230/240 VAC 

Total Power Supply 

Output Rating 

9 A total @ nominal 28 VDC, 

including module currents and 

auxiliary power outputs

Auxiliary Power Tap  2 A maximum @ nominal 28 VDC 

Power Supply Output 
Ratings 

(System, 

Expansion, and Remote 
Power Supplies)

NACs Programmed 

for Auxiliary Power 

2 A maximum per NAC, 5 A maximum @ nominal 28 VDC 

Output switches to 
battery backup 
during mains AC 
failure or brownout 
conditions

Battery capacity range 

6.2 Ah to 50 Ah; selectable via programming for batteries below 18 Ah; the SPS is UL 
listed for up to 110 Ah battery charging for remotely located batteries 

Battery Charger 

(System and Remote 
Power Supply) 

Charger characteristics 

and performance 

Temperature compensated, dual rate, recharges depleted batteries within 48 hours per 
UL Standard 864, to 70% capacity in 12 hours per ULC Standard S527 

Operating Temp. Range  32° to 120°F (0° to 49° C) 

Environmental 

Operating Humidity Range  Up to 93% RH, non-condensing @ 90° F (32° C) maximum 

 MINIPLEX Transponder Product Selection 

(Continued)

 General Specifications 

Содержание MINIPLEX 4100-9600

Страница 1: ...n Off Auto PressACKlocatedunderflashingindicator Repeat operationuntil allevents areacknowledged Localtonew ill silence AB C AC Pow er D E F G H I J K L M N O P Q R SP 0 S T U VW X Y Z ALARMS F ire Al...

Страница 2: ...sensors will alarm at a fixed temperature of 135 F 57 C x TrueAlarm device LEDs will be activated to indicate a device in alarm Local Mode Control Operation Continued Notification Operation Fire alar...

Страница 3: ...ashing Tone On Press Ala rmSilence How to Reset System Press Sy stemReset Press Ack tosilence tone device ZONE 1 SIG 2 AUX 3 FB 4 IO 5 IDNet 6 P 7 A 8 L 9 NET ADDR 0 DEL Enter C Exit Fire Alarm Ack Pr...

Страница 4: ...UL System Power Supply SPS 9 A power supply charger with 250 point IDNet channel 3 Class A B NACs and expansion slot for City Circuit or Alarm Relay option Canadian model has low battery cutout 4 Blo...

Страница 5: ...Model Output Voltage 25 VRMS 70 7 VRMS Power Supply Input Listing Description Details 4100 1328 4100 1329 120 VAC 60 Hz UL 4100 1330 4100 1331 120 VAC 60 Hz ULC 4100 1332 4100 1333 220 230 240 VAC 50...

Страница 6: ...102 MAPNET II Module 127 point capacity add devices separately Module size 2 Slots Loading per MAPNET II device 1 7 mA Fully loaded module total 470 mA 490 mA 4100 3103 Isolator Module for MAPNET II o...

Страница 7: ...20 ft 6 1 m 2 Nine wires required 24 VDC 2 one per LED indicator 4 and one per switch 3 3 Wire size 18 AWG 0 82 mm Expansion Bay Module Loading Reference Description Mounting Transponder Interface Mo...

Страница 8: ...r semi flush mounting 6 stud Optional semi flush trim kit reference Front view box outline without door Side view with door attached 2 Bay height 40 1016 mm Doors can be hinged left or right 3 Bay hei...

Отзывы: