Audio Riser Modules 

Model

Description 

Size

Supv. 

Alarm 

4100-0621 

Dual Channel 

Analog

 Audio Riser Module; accepts one or two separate audio signals from 

host control panel; mounts in Block B, is controlled by Transponder Interface Module 

1 Block 

0 mA 

0 mA 

4100-0622 

3-8 Channel 

Digital

 Audio Riser Module; similar to analog module, except receives and 

decodes a digital input signal with up to eight audio channels; with Non-Alarm Audio input 

1 Block 

50 mA 

50 mA 

Analog

 Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible*

Model

Description 

Details

4100-1361  25 VRMS output 

NAC rating = 1.4 A  

4100-1362  70.07 VRMS output 

Flex-35, 35 W Amplifier, constant 
supervision compatible 

NAC rating = 0.5 A 

35 W, or 100 
speakers

4100-1312  25 VRMS output 

NAC rating = 2 A 

4100-1313  70.7 VRMS output 

Flex-50, 50 W Amplifier, constant 
supervision compatible 

Includes three on-board 
Class B audio NACs; 
power is supplied from 
an XPS, RPS, or SPS 

NAC rating = 0.707 A 

50 W, or 100 
speakers

100 W 

Analog

 Amplifiers with Power Supply, Constant Supervision Compatible 

Model/Output Voltage 

25 VRMS

70.7 VRMS 

Power Supply Input/Listing 

Description 

Details

4100-1314 

4100-1315  120 VAC, 60 Hz 

UL 

4100-1316 

4100-1317  120 VAC, 60 Hz 

ULC 

4100-1318 

4100-1319  220/230/240 VAC, 50/60 Hz 

UL 

Primary 

100 W 

Amplifier 

Includes six, Class B audio NACs;
NAC rating = 50 W or 100 speakers 
maximum; 2 A @ 25 VRMS;  
1.4 A @ 70.7 VRMS 

4100-1320 

4100-1321  120 VAC, 60 Hz 

UL 

4100-1322 

4100-1323  120 VAC, 60 Hz 

ULC 

4100-1324 

4100-1325  220/230/240 VAC, 50/60 Hz 

UL 

Backup

100 W 

Amplifier 

Uses the six Class B NACs of primary 
amplifier 

ULC
models
have low 
battery
dropout
circuit 

Digital

 Emergency Voice/Alarm Communications Equipment*

Model

Description 

Details

4100-1363  25 VRMS output 

NAC rating = 1.4 A  

4100-1364  70.07 VRMS output 

Flex-35, 35 W Amplifier, constant 
supervision compatible 

NAC rating = 0.5 A 

35 W, or 100 
speakers

4100-1326  25 VRMS output 

NAC rating = 2 A 

4100-1327  70.7 VRMS output 

Flex-50, 50 W Amplifier, constant 
supervision compatible 

Includes three on-board 
Class B audio NACs; 
power is supplied from 
an XPS, RPS, or SPS 

NAC rating = 0.707 A 

50 W, or 100 
speakers

100 W 

Digital

 Amplifiers with Power Supply, Constant Supervision Compatible 

Model/Output Voltage 

25 VRMS

70.7 VRMS

Power Supply Input/Listing 

Description 

Details

4100-1328 

4100-1329  120 VAC, 60 Hz 

UL 

4100-1330 

4100-1331  120 VAC, 60 Hz 

ULC 

4100-1332 

4100-1333  220/230/240 VAC, 50/60 Hz 

UL 

Primary 

100 W 

Amplifier 

Includes six, Class B audio NACs;
NAC rating = 50 W or 100 speakers 
maximum; 2 A @ 25 VRMS;  
1.4 A @ 70.7 VRMS 

4100-1334 

4100-1335  120 VAC, 60 Hz 

UL 

4100-1336 

4100-1337  120 VAC, 60 Hz 

ULC 

4100-1338 

4100-1339  220/230/240 VAC, 50/60 Hz 

UL 

Backup

100 W 

Amplifier 

Uses the six Class B NACs of primary 
amplifier 

ULC
models
have low 
battery
dropout
circuit 

Options for use with either Analog or Digital Amplifiers 

Model

Description

Details and Mounting Reference 

4100-1245 

Flex-35/50 Expansion NAC Module; adds three 
Class B audio NACs 

Mounts on Flex-35/50 assembly; NAC ratings = 1.5 A, 35/50 W, 
or 100 speakers maximum; 

Supv = 0.6 mA, Alarm = 60 mA

4100-1246 

Flex-35/50 Class A Adapter Module; converts 
three on-board NACS to Class A operation 

Choose
one per 

amplifier 

Mounts on Flex-35/50 assembly; NAC ratings = 2 A, 50 W, or 
100 speakers maximum; 

Supv = 0, Alarm = 30 mA

4100-1248 

100 W Amplifier Expansion NAC Module; NAC 
ratings = 1.5 A, 50 W, or 100 speakers max. 

Provides six additional Class B audio NACs, mounts on 100 W 
amplifier assembly; 

Supv = 1.2 mA, Alarm = 120 mA

4100-1249 

100 W Class A Adapter Module; NAC ratings = 
2 A, 50 W, or 100 speakers max. 

Choose
one per 
amplifier 

Converts six on-board NACs to Class A operation, mounts on 
100 W amplifier assembly; 

Supv = 0, Alarm = 60 mA

4100-1259 

25 VRMS Output; NAC 
rating = 2 A, 50 W, or 100 
speakers max. 

Supv = 10 mA 
Alarm = 35 mA

4100-1260 

70.7 VRMS Output; NAC 
rating = 0.707 A, 50 W, or 
100 speakers max. 

Constant Supervision 
Adapter for three NACs; 
select per amplifier output 
(not compatible with amplifier 
NAC expansion modules) 

Supv = 38 mA 
Alarm = 60 mA

Converts three Class B audio NACS to 
Class A or Class B Constant Supervision 
NACs; mounts on Flex-35/50 or 100 W 
amplifier assembly; use two for the six NACs 
on 100 W amplifiers;

Firefighters Telephone Options 

Model

Description

Size

Supv. 

In Use 

4100-1272 

Expansion Telephone Control Module with three Class B telephone NACS; required when 
telephone circuits are mounted in transponder;  

1 Block 

75 mA 

329 mA 

max. 

4100-1273  Telephone Class A Adapter Module; mounts on 4100-1272; no additional current required 

* Refer to document S4100-0034 for additional audio information.

 

Continued on next page

 MINIPLEX Transponder Product Selection

 (Continued)

Содержание MINIPLEX 4100-9600

Страница 1: ...n Off Auto PressACKlocatedunderflashingindicator Repeat operationuntil allevents areacknowledged Localtonew ill silence AB C AC Pow er D E F G H I J K L M N O P Q R SP 0 S T U VW X Y Z ALARMS F ire Al...

Страница 2: ...sensors will alarm at a fixed temperature of 135 F 57 C x TrueAlarm device LEDs will be activated to indicate a device in alarm Local Mode Control Operation Continued Notification Operation Fire alar...

Страница 3: ...ashing Tone On Press Ala rmSilence How to Reset System Press Sy stemReset Press Ack tosilence tone device ZONE 1 SIG 2 AUX 3 FB 4 IO 5 IDNet 6 P 7 A 8 L 9 NET ADDR 0 DEL Enter C Exit Fire Alarm Ack Pr...

Страница 4: ...UL System Power Supply SPS 9 A power supply charger with 250 point IDNet channel 3 Class A B NACs and expansion slot for City Circuit or Alarm Relay option Canadian model has low battery cutout 4 Blo...

Страница 5: ...Model Output Voltage 25 VRMS 70 7 VRMS Power Supply Input Listing Description Details 4100 1328 4100 1329 120 VAC 60 Hz UL 4100 1330 4100 1331 120 VAC 60 Hz ULC 4100 1332 4100 1333 220 230 240 VAC 50...

Страница 6: ...102 MAPNET II Module 127 point capacity add devices separately Module size 2 Slots Loading per MAPNET II device 1 7 mA Fully loaded module total 470 mA 490 mA 4100 3103 Isolator Module for MAPNET II o...

Страница 7: ...20 ft 6 1 m 2 Nine wires required 24 VDC 2 one per LED indicator 4 and one per switch 3 3 Wire size 18 AWG 0 82 mm Expansion Bay Module Loading Reference Description Mounting Transponder Interface Mo...

Страница 8: ...r semi flush mounting 6 stud Optional semi flush trim kit reference Front view box outline without door Side view with door attached 2 Bay height 40 1016 mm Doors can be hinged left or right 3 Bay hei...

Отзывы: