4 Initial operation
4.1 Programming
(For programming for SmartIntego, see Step-by-Step Guide).
4.2 Measurement and calculation
1. Measure the distance between the inside of the door and the dead-bolt
stop (A), e.g. with the depth rod of a caliper gauge.
2. Measure the thickness of the door/door panel (B).
3. Refer to the tables for the parts required from the scope of delivery (ad-
apter plates, dead-bolt fixture, flange extensions and screw). Additional
parts can be ordered (see manual).
Inner side of door up to dead-bolt
stop (A)
Adapter plate P
(LL.PLATE5)
Dead-bolt fix-
ture R
0.0 mm to 5.95 mm
None
4 (5.9 mm)
6.05 mm to 7.25 mm
None
3 (7.5 mm)
7.35 mm to 8.85 mm
None
2 (9.1 mm)
8.95 mm to 10.45 mm
None
1 (10.4 mm)
10.55 mm to 10.95 mm
5 mm
4 (5.9 mm)
11.05 mm to 12.25 mm
5 mm
3 (7.5 mm)
12.35 mm to 13.85 mm
5 mm
2 (9.1 mm)
13.95 mm to 15.45 mm
5 mm
1 (10.4 mm)
15.55 mm to 15.95 mm
2 × 5 mm
4 (5.9 mm)
16.05 mm to 17.25 mm
2 × 5 mm
3 (7.5 mm)
SI SmartLocker AX