To assess compatibility, please note the following information:
Wooden doors
The door must be between 10 mm and 25 mm thick.
With metal spindles, at least two adapter plates must therefore be
used for standard material thicknesses (1 mm to 2 mm).
Depending on the bolt block, the bolt has a clearance of 5.9 mm to
10.4 mm from the claw of the engine block. If necessary, you must
attach adapter plates to the door frame so that the bolt rests on the
door frame without play and the door does not fold.
Metal doors
The door panel and adapter plates must be between 10 mm and
25 mm thick altogether.
With metal spindles, at least two adapter plates must therefore be
used for standard material thicknesses (1 mm to 2 mm). However, due
to the rebate in the door or frame, the use of adapter plates is usually
required anyway.
The deadbolt stop of the frame may not be more than 30.4 mm from
the inside of the door when closed.
The distance between the outside of the door and the inside of the bolt
must not exceed 35.4 mm. This means that the maximum height of the
rebate for metal doors is 10.4 mm (A).
9.2 Drawings of installation situations
Lockers and cupboards are available in many different designs. Compare
your locker or cupboard with the drawings below to assess your personal
installation situation.
SI SmartLocker AX
(Manual)
9. Technical specifications
30 / 36