Module
Address
Module 15
E
1.
Press the sides of the transparent inlay together.
2. Remove the transparent inlay.
3. Use a screwdriver to configure the address as per
the table.
4. Insert the transparent inlay again.
10 Signal
10.1 LEDs for each output
Each of the eight outputs has an assigned LED. This
LED indicates the output's status.
Green
Output closed
Off
Output open
10.2 Status LED
There is also a three-colour RGB LED which indicates
the SmartOutput module's status.
Lights up green every five seconds
Communication with SmartRelay
OK
Lights up red every five seconds
Communication with SmartRelay
disrupted (e.g. bus line busy due to
communication by other modules)
Flashes green/red
Communication is taking place
with SmartRelay
Flashes red
Supply voltage too low
MOD.SOM8
10. Signal
34 / 140
EN