1. 

       BASIC REQUIREMENTS AND USER SAFETY

 

 

-

 The manufacturer is not responsible for any damages caused by 

inappropriate installation, not maintaining the proper technical condition  
and using the unit against its destination .

- Installation should be conducted by qualified personnel . During installation all  

available safety requirements should be considered. The fitter is responsible for  

executing the installation according to this manual, local safety and EMC  

regulations.

- The unit must be properly set-up, according to the application. Incorrect  

configuration can cause defective operation, which can lead to unit damage or  

an accident. 

If in the case of a defect of unit operation there is a risk of a serious threat  

to the safety of people or property additional, independent systems and  
solutions to prevent such a threat must be used.

-  

The unit uses dangerous voltage that can cause a lethal accident. The unit  

must be switched off and disconnected from the power supply prior to  
starting installation of troubleshooting (in the case of malfunction).

- Neighbouring and mating equipment must meet the requirements of appropriate  

standards and regulations concerning safety and be equipped with adequate  

anti-overvoltage and anti-interference filters.

-

 Do not attempt to disassemble, repair or modify the unit yourself. The unit  

has no user serviceable parts. Units, in which a defect was stated must be  
disconnected and submitted for repairs at an authorized service centre.

- Do not use the unit in areas threatened with excessive shocks, vibrations,  

corrosive gasses and oils.

- Do not use the unit in explosion hazard areas.

- Do not use the unit in areas with significant temperature variations, exposed to  

icing.

- Do not use the unit in areas exposed to direct sunlight. 

- Make sure that the ambient temperature (e.g. inside the control box) does not  

exceed the recommended values. In such cases forced cooling of the unit must  

be considered (e.g. by using a ventilator).

The unit is designed for operation in an industrial environment and must  
not be used in a household environment or similar. 

3

Содержание TRS-09a

Страница 1: ...6 User manual POWER SUPPLY TRS 09a Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to implement changes without prior n...

Страница 2: ...n of symbols used in the manual This symbol denotes especially important guidelines concerning the installation and operation of the device Not complying with the guidelines denoted by this symbol may...

Страница 3: ...ched off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate...

Страница 4: ...efficiency max 200 mA Control voltage 7V 12V DC max 2mA Protection level IP 65 ABS casing Housing type Housing material Housing dimensions L x W x D without glands with glands wall mounted ABS 110 x 8...

Страница 5: ...etwork voltage corresponds to the nominal voltage stated on the unit s identification label The load must correspond to the requirements listed in the technical data All installation works must be con...

Страница 6: ...circuit breaker located near the unit In the case of using a monopolar fuse it must be mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the...

Страница 7: ...ransmission cables together with power supply cables and cables controlling induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equip...

Страница 8: ...nes connectors GND GND of supply output and control input Figure 4 4 Connection of TRS 09a module to the network 8 5 8 7 6 4 3 1 2 DATA DATA RS 485 ctrl GND 12V out shield 230V AC J1 J2 LED indicator...

Страница 9: ...network at the same time When power supply of first TRS 09a module is turned off then following power supply modules will be turned off sequentially Figure 4 6 Cascade of power supply modules TRS 09a...

Страница 10: ...rked with this symbol should not be placed in municipal waste Please check local regulations for disposal and electronic products 5 SELECTION OF OPERATION MODE The selection of operation mode can be d...

Страница 11: ...User manual POWER SUPPLY TRS 09a Figure 5 1 Selection of operation mode 11 5 8 7 6 4 3 1 2 J1 J2 Operation mode selection jumpers J1 J2 J1 J2 J1 J2 Stand alone mode Externally controlled mode or...

Страница 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Отзывы: