User manual - POWER SUPPLY TRS-09a 

2. 

       GENERAL CHARACTERISTICS

 

 

TRS-09a

  is a supporting power  supply for the TRS System which  supplies stabilized  

direct  voltage  11.5V.  It can  work  in  two  modes: as a  controlled   supply  (switched  on  with  

external voltage 7 ÷ 12V) or a non-controlled supply. The configuration is selected by means of  

a link. Current efficiency is 200 mA. The supply is resistant to output voltage short circuit. The  

device is located in a casing that completely protects it against dust or low pressure streams of  

water.

3. 

       TECHNICAL DATA

 

 

Power supply voltage

230V AC 

+10%, -5%,  50 ÷ 60 Hz

External fuse (required)

T - type, max. 2 A

Power consumption

max. 6 VA

Output voltage

11.5 V ±5% DC

Current efficiency

max. 200 mA

Control  voltage

7V ÷ 12V DC, max. 2mA

Protection level

IP 65 (ABS casing)

Housing type

Housing material

Housing dimensions (L x W x D)

without glands

with 

glands

wall mounted

ABS

110 x 80 x 67 mm

133 x 130 x 67 mm

Operating temperature

(depending on version)

0°C to +50°C

or -20°C to +50°C

Storage temperature

(depending on version)

-10°C to +70°C

or -20°C to +70°C

Altitude

up to 2000 meters above sea level

Fastening

to wall, 2 M3 bolts

Connection cable

4 conductors (2 supply conductors 

+ 2 data transmission conductors)

Screws tightening max. torque

0,5 Nm

Max. connection leads diameter

2,5 mm

2

Safety requirements 

according to:

PN-EN 61010-1:1999 + PN-EN 61010-1/A2:1999

installation category: II

pollution degree: 2

voltage in relation to ground: 300V AC

insulation resistance

: >20M

 

insulation strength between power supply and input/output  

terminal: 1min. @ 2300V

EMC

PN-EN 61326:2003

4

Содержание TRS-09a

Страница 1: ...6 User manual POWER SUPPLY TRS 09a Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to implement changes without prior n...

Страница 2: ...n of symbols used in the manual This symbol denotes especially important guidelines concerning the installation and operation of the device Not complying with the guidelines denoted by this symbol may...

Страница 3: ...ched off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate...

Страница 4: ...efficiency max 200 mA Control voltage 7V 12V DC max 2mA Protection level IP 65 ABS casing Housing type Housing material Housing dimensions L x W x D without glands with glands wall mounted ABS 110 x 8...

Страница 5: ...etwork voltage corresponds to the nominal voltage stated on the unit s identification label The load must correspond to the requirements listed in the technical data All installation works must be con...

Страница 6: ...circuit breaker located near the unit In the case of using a monopolar fuse it must be mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the...

Страница 7: ...ransmission cables together with power supply cables and cables controlling induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equip...

Страница 8: ...nes connectors GND GND of supply output and control input Figure 4 4 Connection of TRS 09a module to the network 8 5 8 7 6 4 3 1 2 DATA DATA RS 485 ctrl GND 12V out shield 230V AC J1 J2 LED indicator...

Страница 9: ...network at the same time When power supply of first TRS 09a module is turned off then following power supply modules will be turned off sequentially Figure 4 6 Cascade of power supply modules TRS 09a...

Страница 10: ...rked with this symbol should not be placed in municipal waste Please check local regulations for disposal and electronic products 5 SELECTION OF OPERATION MODE The selection of operation mode can be d...

Страница 11: ...User manual POWER SUPPLY TRS 09a Figure 5 1 Selection of operation mode 11 5 8 7 6 4 3 1 2 J1 J2 Operation mode selection jumpers J1 J2 J1 J2 J1 J2 Stand alone mode Externally controlled mode or...

Страница 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Отзывы: