User manual for digital clock SWZ-W610
Inputs
temperature sensor:
DCF77 receiver:
designed to digital temperature sensor, 2-wire
connection
the receiver output NPN or push-pull type, signal with
positive or negative polarization
Displaying range
time:
date:
temperature (option):
24h format : hours, minutes seconds
day of month, month, 2 last digits of year
-40°C to 85°C, resolution: 1°C
Internal clock battery
non-removable, 3V, Li
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
LED, 4 digit 100mm 2 digit 57mm height, red,
with 8-steps brightness regulation
Data memory
non-volatile memory, EEPROM type
Protection level
IP 30
Housing type
Housing material
Housing dimensions
Wall mounted
alu methyl polimethacrylate
578 x 208 x 102 mm
Operating temperature
Storage temperature
0°C to +50°C
-10°C to +70°C
Humidity
Altitude
5 to 90% no condensation
up to 2000 meters above sea level
Screws tightening max. torque
0.5 Nm
Max. connection leads diameter
2.5 mm
2
Safety requirements
according to: PN-EN 61010-1
installation category: II
pollution degree: 2
voltage in relation to ground: 300V AC
insulation resistance
: >20M
Ω
insulation strength between power supply and
input/output terminal: 1min. @ 2300V
EMC
according to: PN-EN 61326
This is a class A unit. In housing or a similar area it can cause radio
frequency interference. In such cases the user can be requested to use
appropriate preventive measures.