User manual for digital clock SWZ-W610

If displaying periods of all readings are set to zero, then successive pressing of  

“ENTER” 

button switches readings, and they are displayed permanently.

  All   accessible   parameters   can   be   changed   by   entering   the   menu   (see:  

DEVICE 

PROGRAMMING

).   Use   the   local   keyboard   or   the   remote   controller   to   do   it.   (Note:   all 

parameters can be remote changed via RS-485  interface).

Configuration of  the device  (via menu or RS 485 interface) 

do not stops device

.

6.2. 

  

    THERMOMETER FUNCTION

  

The 

SWZ-W610 

is equipped with {

THERM

} input. It allows to connect digital thermometer 

module (optional) to the device. To enable displaying of temperature in the sequence,   the 
thermometer function must be on (parameter 

”thEr”

 of 

”Func” 

menu set to 

”on”

). Parameter 

”dL  t”

 (available only while thermometer function is on) defines display time of temperature. 

6.2.1. 

  

    Temperature sensor module installation

  

Avoid of mounting

 the module near of the doors, windows (specially near of rooms with 

different   temperature),   in   places   of   high   air   flow,   sunny   places   and   near   of   artificial   light 

sources (like bulbs) etc.

Due   to   possibility   of   electromagnetic   noise   while   using   long   connection   wires, 

a temperature sensor should be equipped with denoising filter.

Figure 6.1. Connection of temperature sensor module to 

SWZ-W610

6.3. 

  

    SYNCHRONIZATION OF  THE CLOCK WITH DCF77 SIGNAL

  

The DCF77 is a radio signal contained informations about current time (central Europe). 

Sending time is official UE time. Amplitude modulated signal is sent in LW band on 77.5 kHz 

frequency.   The transmitter  is  placed  in  Mainflingen,   near  of   Frankfurt   (Germany),   and  has 

about 2500km of coverage (power about 50 kW). There are coded informations about current 

hour, minute,  date, day of week in the signal, and they are synchronized to high-precision 

atomic time standard. One  data pocket is transmitted over 59 seconds.

6.3.1. 

  

    Installation of  DCF77 module

  

To obtain proper reception of DCF77 signal, correct location and orientation of receiver 

aerial is essential. Due to DCF77 receivers are usually sensitive to electromagnetic noise (also 

generated by computers, monitors, TV sets, motors  and other devices), it is recommended to 

12

12 13

GND

temperature

sensor

module

data line

i

i

Содержание SWZ-W610

Страница 1: ...for digital clock type SWZ W610 firmware version 1 01 or higher Read the user s manual carefully before starting to use the unit Producer reserves the right to implement changes without prior notice...

Страница 2: ...ation of DCF77 module 12 7 DEVICE PROGRAMMING 14 7 1 PROGRAMMING MENU 14 7 2 PARAMETERS EDITION 14 7 2 1 Numeric parameters digit change mode 14 7 2 2 Numeric parameters slide change mode 15 7 2 3 Swi...

Страница 3: ...up according to the application Incorrect configuration can cause defective operation which can lead to unit damage or an accident If in the case of a defect of unit operation there is a risk of a ser...

Страница 4: ...mode only and internal battery preserves proper time counting even if device is turned off from power supply The SWZ W610 is designed to operate in closed rooms where relative humidity is lower than 9...

Страница 5: ...on volatile memory EEPROM type Protection level IP 30 Housing type Housing material Housing dimensions Wall mounted aluminium methyl polimethacrylate 578 x 208 x 102 mm Operating temperature Storage t...

Страница 6: ...y Protecting the power supply clamps against unauthorized persons must be taken into consideration 4 1 UNPACKING After removing the unit from the protective packaging check for transportation damage A...

Страница 7: ...mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the case of a short circuit of the cable from the side of the unit the cable shall be protec...

Страница 8: ...g induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equipped with anti interference protection systems e g RC type Use of screened...

Страница 9: ...Earth terminal is 2 Nm Power supply connection must be made using 3 wire cord After installation power cord gland should be tighten up to prevent cable move Metal housing must be connected with PE gro...

Страница 10: ...ry cloth In the case of more significant contamination use warm water with small amount of detergent to wet the cloth Using any other agents can cause permanent damage to the housing Product marked wi...

Страница 11: ...tal temperature sensor module is connected to THERM input the device can display current temperature near the sensor The display can show only one of these parameters or can change them in sequence wi...

Страница 12: ...f high air flow sunny places and near of artificial light sources like bulbs etc Due to possibility of electromagnetic noise while using long connection wires a temperature sensor should be equipped w...

Страница 13: ...LED is on should be shorter than time while LED is dark The additional test of correct orientation of the aerial is number of received bits see parameter Sync of dCF submenu Aerial should be oriented...

Страница 14: ...ion of ENTER button depend on present menu position if the name of some sub menu is displayed enter this sub menu name of the first parameter or next level sub menu is displayed if the name of some pa...

Страница 15: ...ncel the changes press ESC button shortly after SEt is displayed After that device returns to the menu 7 2 3 Switch parameters LIST type Switch parameters can be described as a sets of values a lists...

Страница 16: ...parameter to 00 causes in permanent displaying of time after switch device to display it dL d this parameter defines the displaying period of current date in format day month year in range from 1 to...

Страница 17: ...eived data the double dot between hour and minutes will start to pulse in asymmetrical mode lighting time much shorter than time of dimming diSP this parameter allows to on off the signalisation of DC...

Страница 18: ...to 199 If the value 0 is set then device responds to frames with address 255 FFh Every SWZ W610 connected to the same serial network should have its own address different from other devices addressed...

Страница 19: ...ble by the one use password To get this password please contact with Marketing Division Single use password can be used only one time after that it is destroyed Entering this password causes in cleari...

Страница 20: ...n 4 digit user password entering if it is different from 0000 thEr MENU ESC rS MENU ESC dEFS ENTER MENU ESC MENU ESC SErv Parameter edition ENTER MENU ESC ENTER ENTER MENU ESC Addr bAud mbAC rESP MENU...

Страница 21: ...Monday etc 11h Yes 2000 2099 Year registry 12h Yes 1 12 Months registry 13h Yes 1 31 Days registry 14h Yes 0 23 Hours registry 15h Yes 0 59 Minutes registry 16h Yes 0 59 Seconds registry 17h Yes see d...

Страница 22: ...eter in Func menu date displaying 0 disabled 1 enabled 39h Yes 0 1 yEAr parameter in Func menu display year while date 0 disabled 1 enabled 3Ah Yes 0 1 thEr parameter in Func menu temperature displayi...

Страница 23: ...ield description ADDR Device address on modbus network FUNC Function code REG H L Starting address address of first register to read write Hi and Lo byte COUNT H L No of registers to read write Hi and...

Страница 24: ...H 07 D5 00 05 00 17 EA BA This write causes by setting the date to 23th of may 2005 Device s answer ADDR FUNC REG H L COUNT H L CRC L H 01 10 00 01 00 03 D1 C8 4 Try to write improper value to registe...

Страница 25: ...ng on 17 yEAr Enable disable of year displaying while date displaying on 17 thEr Enable disable of temperature displaying oFF 17 DCF77 signal receiver configuration dCF menu modE Enable disable of syn...

Страница 26: ...User manual for digital clock SWZ W610 26...

Страница 27: ...User manual for digital clock SWZ W610 27...

Страница 28: ...SIMEX SIMEX Sp z o o ul Wielopole 7 PL 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex com pl e mail info simex com pl...

Отзывы: