Functions of buttons when editing numeric and switching parameters:
While editing numeric parameter:
•
change of current (flashing) digit
•
slide change of value (acceleration, deceleration, direction change)
While editing switch parameter - selection of switch parameter.
If numerical parameter is being edited, a short press of
[ENTER]
button
change edited position. A long press of
[ENTER]
button (at lest 2 sec.)
causes of display a
”SEt?”
ask, which allow user to make sure if change of
the parameter value is correct. If switch parameter is being edited, a short
press of
[ENTER]
button causes of display a
”SEt?”
ask. When
[ENTER]
button is pressed again (while
”SEt?”
is displayed) the new value of the
parameter is stored in EEPROM memory.
Pressing this button operator can cancel the changes done up to now (if they
were not approved by
[ENTER]
button after the
”SEt?”
ask) and come back
to menu
7.3.
MENU DESC
RIPTION
“Cd 0 - - -”
Password checking. If password is set different from „
0000
”, than every enter to
main menu follows the entering of password. If entered password is correct first
menu position else warning ”
Error
” will be displayed, and unit returns to
measurement mode.
Due to problem with direct displaying of “
m
” letter, it is exchanged with special sign
“ “. Independently in user manual letter „
m
” is used to make it more readable
(example:
“modE”
).
7.3.1.
“rELAy” menu
This menu allows to configure the operation mode of relays and LEDs marked „
R
” (e.g.
„
R1
”). If there are few relay outputs available, then every output has its own configuration
menu (e.g. menu „
rELAy2
” for relay (LED) „
R2
”). Principle of the relays operation is described
in paragraph
CONTROL OF THE RELAY OUTPUTS
.
If
”PArUPd”
option is set to
”on rES”
mode, then change of parameters
”muL”
,
”div”
,
”oFFSEt”, ”Point”
and all parameters of the relays controlling (see
”rELAy”
menu), has no influence on current counting process. In this mode changed
parameters will be applied after reset (manual or automatic) or next device power
up. If
”PArUPd”
option is set to
”immEd”
mode, then all changes of these
parameters are applied immediately.
“SEtP”
- threshold of the relay (range -99999 ÷ 999999). Negative values can be input by
selecting a “-” sign on first digit (to change value use
[^]
and
[v]
buttons).
“modE”
- relay operation mode, this parameters define the
active state
of the relay, it
means state of relay while the counter reaches
threshold
value
, at “up counting”,
available modes:
26
i
MENU
ESC
ENTER
i