![Simex Simpact SLIK-73 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/simex/simpact-slik-73/simpact-slik-73_user-manual_1275341028.webp)
User manual for universal counter with batching function SLIK-73
”Std”
- answer as quick as possible, no additional delay
” 10c”
” 20c”
” 50c”
”100c”
”200c”
- answer delayed of 10, 20, 50, 100 of 200 chars respectively, where
one character time depends on selected baud rate
In the most cases parameter
”rESP”
should be set to
”Std”
(no additional delay).
Unfortunately for some third party RS-converters
”rESP”
should be adjusted
experimentally. Table 7.1 contains most frequently used values.
”bAud” parameter
“38.4”
“57.6”
“115.2”
”rESP” parameter
“ 10c”
“ 20c”
“ 50c”
Tab.7.1. Settings of ”rESP” parameter
7.3.9.
”SECu” menu
This menu contains presets connected with availability of other parameters:
“SEtCod”
- user password (4-digits number). If this parameter is set at value
“0000”
, user
password is turned off.
If the user do not remember his password, the access to the menu is possible
by the “one-use password”. To get this password please contact with
Marketing Division. “Single use password” can be used only one time, after
that it is destroyed. Entering this password causes in clearing of user
password, it means sets the user password to „0000”.
The “one-use password” can be used
ONE TIME ONLY
, it is impossible to use it
again! The “one-use password” can be restored by Service Division only.
“A rEL”
- this option permits user (
”on”
) or prohibits (
”oFF”
) to modify the threshold of the
relays/LED R1 without knowledge about user password.
The diagram of quick view mode is presented in figure 7.1.
28
i
i