background image

Safety / General Information

2

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury.

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The label 

NOTICE 

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

DESCRIPTION

Simer laundry pump system, Model number 2925B-01, is
ideal for home wastewater removal from sinks and wet
bars and for drain water transfer from air conditioners or
dehumidifiers. The 3/10 HP submersible pump is
equipped with a 3-prong grounding-type power cord.
Motor is oil filled and sealed for cooler running. Upper
sleeve/lower ball bearings on motor shaft never need
lubrication. Automatic reset thermal protection.

NOTICE:

This unit is not designed for applications involv-

ing salt water or brine! Use with salt water or brine will
void warranty.

ELECTRICAL & FLOAT SWITCH 
SPECIFICATIONS

SPECIFICATIONS

Power Supply Required .............................115V, 60 HZ.
Liquid Temp. Range ...............32° F to 120° F (0°-49° C)
Individual Branch Circuit 
Required (minimum) .........................................15 Amps
Discharge ...................................................1-1/4" MNPT

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump’s capacity, electri-
cal or mechanical failure in the pump, etc.) may prevent
your pump from functioning normally. To prevent possi-
ble water damage due to flooding, consult your dealer
about installing a high water alarm. See the
“Troubleshooting Chart” in this manual for information
about common sump pump problems and remedies. 
For more information, see your dealer or call customer
service at 1-800-468-7867 or 1-800-546-7867.
1. Know the pump application, limitations, and poten-

tial hazards.

2. Disconnect the power before servicing.
3. Release all the pressure within the system before ser-

vicing any component.

4. Drain all the water from system before servicing.
5. Secure the discharge line before starting the pump.

An unsecured discharge line will whip, possibly caus-
ing personal injury and/or property damage.

6. Check the hoses for a weak or worn condition before

each use, making certain that all connections are
secure.

7. Periodically inspect the system components. Keep

free of debris and foreign objects. Perform routine
maintenance as required. 

8. Provide a means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times when working with

pumps.

b. Keep the work area clean, uncluttered and properly

lighted – replace all unused tools and equipment.

c. Keep visitors at a safe distance from the work area.
d. Make the workshop child-proof – with padlocks,

master switches, and by removing starter keys.

10. When wiring an electrically driven pump, follow all

electrical and safety codes that apply.

11.

This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc-
tor cord and 3-prong, grounding-type plug.

To reduce risk of electric shock, pull

plug before servicing. This pump has not been inves-
tigated for use in swimming pool areas.

Pump is sup-

plied with a grounding conductor and grounding-type
attachment plug. Be sure it is connected only to a
properly grounded grounding-type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.

12. All wiring should be performed by a qualified 

electrician.

Motor

*Switch Setting

Motor

Full Load

in inches (mm)

Series

HP

Amps

On

Off

2925B-01

3/10

10.0

7" (178)

2" (51)

Содержание 2925B

Страница 1: ...468 7867 Fran ais Pages 8 13 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 468 7867 Espa ol Paginas 14 19 2004 PRIN...

Страница 2: ...ormally To prevent possi ble water damage due to flooding consult your dealer about installing a high water alarm See the Troubleshooting Chart in this manual for information about common sump pump pr...

Страница 3: ...astics 3 A short length of rubber hose 1 7 8 47 6 mm I D or a quick disconnect should be attached to the dis charge line This will help when removing the pump for maintenance A rubber hose may also da...

Страница 4: ...should be removed and checked for the cause of the difficulty Low voltage long extension cords a clogged impeller very low head or lift etc could cause cycling Refer to the Troubleshooting Chart on Pa...

Страница 5: ...o improper operation premature pump failure and flooding Risk of Electric shock Shock can burn or cause death When servicing the system always discon nect power cord from the electrical outlet To Repl...

Страница 6: ...f proper size or run Low line voltage If the voltage is under the recommended minimum check the size of the wiring from the main switch on the property If OK contact power company or hydro authority D...

Страница 7: ...67 Repair Parts 7 Key No Description Qty Part No 1 10 Gallon Poly Basin Assembly 1 PS51 1P 2 Automatic Vertical Float Switch 1 PKG 208 3 Check Valve 1 ZB902110 4 3 10 HP Submersible Sump Pump 1 2957 0...

Страница 8: ...v d eau Se reporter au tableau Recherche des pannes de cette Notice pour tout renseignement concernant les prob l mes les plus courants des pompes de puisard et comment y rem dier Pour de plus amples...

Страница 9: ...m tre int rieur ou un dispositif de branchement rapide doit tre branch sur la conduite de refoulement Ceci per mettra de d poser la pompe pour l entretenir Un tuyau souple en caoutchouc peut galement...

Страница 10: ...s d bris Proc der l entretien p riodique selon le besoin Risque d inondation Les inondations risquent de causer des blessures corporelles ou des dommages mat riels Ce sys t me de pompage de buanderie...

Страница 11: ...e la mort Pour inter venir sur le syst me toujours d brancher le cordon lectrique de la prise de courant Pour remplacer l interrupteur flotteur NOTA L interrupteur flotteur doit toujours pouvoir se d...

Страница 12: ...de calibre ad quat pas ou ne fonctionne Tension de ligne basse Si la tension est inf rieure la tension minimale recommand e pas v rifier le calibre des conducteurs de l interrupteur principal de la pr...

Страница 13: ...N de pi ce 1 Bassin en plastique de 38 litres 10 gallons 1 PS51 1P 2 Interrupteur flotteur vertical fonctionnement automatique 1 PKG 208 3 Clapet de non retour 1 ZB902110 4 Pompe de puisard submersibl...

Страница 14: ...stalaci n de una alarma de nivel alto de agua Consulte la Lista de localizaci n de Fallas en este manual para obtener informaci n sobre los proble mas comunes con bombas de sumidero y sus soluciones P...

Страница 15: ...positi vo de desconexi n r pida en la l nea de descarga Esto ser til cuando se deba retirar la bomba para los trabajos de man tenimiento Una manguera de caucho tambi n puede servir para amortiguar el...

Страница 16: ...alice los trabajos de mantenimiento rutinario que se requieran Riesgo de inundaci n Las inundaciones pueden ocasionar lesiones personales o da os materiales Este Sistema de bomba de lavadero viene con...

Страница 17: ...n el sistema siempre desconecte el cord n el ctrico del tomacorriente Para cambiar el interruptor de flotador AVISO El flotador debe poder completar todo su ciclo sin interfer encia de ning n otro obj...

Страница 18: ...i la tensi n se encuentra por debajo del m nimo recomendado verifique el tama o de los cables desde el interruptor principal en la propiedad Si es correcto comun quese con la empresa de energ a o con...

Страница 19: ...n Cant repuesto No 1 Unidad de compartimiento de polietileno de 38 litros 10 galones 1 PS51 1P 2 Interruptor de flotador vertical autom tico 1 PKG 208 3 V lvula de retenci n 1 ZB902110 4 Bomba de sumi...

Страница 20: ...ty This warranty shall not apply to acts of God nor shall it apply to products which in the sole judgement of SIMER have been subject to negligence abuse accident misapplication tampering alteration n...

Отзывы: