background image

For parts or assistance, call Simer Customer Service at 

800-468-7867 / 800-546-7867

Installation • Operation 

3

Performance

Installation

1.  Install tethered switch models in a sump pit with a 

minimum diameter of 14” (356mm). Install vertical switch 

models in a sump pit with a minimum diameter of 11” 

(280mm). Construct the sump pit of tile, concrete, steel or 

plastic. Check the local codes for approved materials.

 

The pump should not be installed on clay, earth or sand 

surfaces. Clean the sump pit of small stones and gravel 

which could clog the pump. Keep the pump suction 

housing clear of debris.

2.  Install the pump in the pit so the switch operating 

mechanism has maximum possible clearance.

3.  Install an in-line check valve to prevent flow backwards 

through the pump when the pump shuts off.

4.  Install the discharge plumbing.

A. When using rigid pipe, use plastic pipe. Wrap the 

discharge pipe thread with PTFE pipe thread sealant tape. 

Screw the pipe into the pump discharge port hand tight 

+1 – 1-1/2 turns.

  NOTICE Do not use ordinary pipe joint compound on 

plastic pipe. Pipe joint compound can attack plastics.

  NOTICE Thread the discharge pipe into the pump body 

carefully to avoid stripping or crossing threads.

B.  If a flexible discharge hose is used, make sure the pump 

is secured in the sump to prevent movement. Do not use 

a flexible discharge pipe in any permanent installation. 

 

 

Risk of flooding. Can cause personal 

injury and/or property damage. Failure to secure pump 

may allow pump movement, switch interference and 

prevent pump from starting or stopping. 

  NOTICE The discharge piping should be as short as 

possible to reduce pipe friction losses. Discharge pipe 

diameter should be equal to or larger than the discharge 

size of the pump. Smaller pipe diameters will restrict the 

capacity of the pump and reduce pump performance. 

C. Secure the discharge line before starting the pump.
  To reduce motor noise and vibrations, a short length of 

rubber hose (e.g. radiator hose) can be connected into 

the discharge line near the pump using suitable clamps. 

If the pump discharge line is exposed to outside sub-

freezing atmosphere, the portion of the line exposed 

must be installed so any water remaining in the pipe 

will drain to the outfall by gravity. Failure to do this can 

cause any water trapped in the discharge line to freeze 

which could result in damage to pump. 

5.  Power Supply: This pump is designed for 115 V., 60 Hz., 

operation and requires a minimum 15 amp individual 

branch circuit. Both the pump and switch are supplied with 

3-wire cord sets with grounding-type plugs. The switch plug 

is inserted directly into the outlet and the pump plug inserts 

into the opposite end of switch plug.

 

 Risk of electric shock. Can shock, burn or 

kill. Pump is supplied with a grounding conductor and 

grounding-type attachment plug. To reduce the risk of 

electric shock, be certain that it is connected only to a 

properly grounded, grounding type receptacle such as 

a grounded water pipe or a properly grounded metallic 

raceway or ground wire system. Ground terminal on 

pump cord plug is provided for your protection. DO NOT 

REMOVE!

 

A ground fault circuit interrupter is recommended for use 

with any electrical appliance submerged in water. For 

installation of such a circuit, consult a licensed electrician.

6.  After the piping and the check valve (if needed) have been 

installed, the unit is ready for operation

7.  Check the operation by filling the sump with water and 

observing pump operation through one complete cycle.

 

 

Risk of flooding. Can cause personal injury 

and/or property damage. Failure to make this operational 

check may lead to flooding and premature failure.

Operation

 Risk of electric shock. Can shock, burn or kill. 

Do not handle a pump or pump motor with wet hands or 

when standing on wet or damp surface, or in water.
1.  Keep the pump inlet screen clear.
2.  The shaft seal depends on water for lubrication. Do not 

operate the pump unless it is submerged in water as the 

seal may be damaged if the pump is allowed to run dry.

3.  The motor is equipped with an automatic reset thermal 

protector. If the temperature in the motor should rise 

unduly, the switch will cut off all of the power before any 

damage can be done to the motor. When the motor has 

cooled sufficiently, the switch will reset automatically 

and restart the motor. If the protector trips repeatedly, the 

pump should be removed and checked for the cause of 

the difficulty. Low voltage, long extension cords, a clogged 

impeller, very low head or lift, etc., could cause cycling. 

Refer to the “Troubleshooting Chart”.

 

 

 

 Individual  

Switch 

Setting

 

Model 

 

Max. 

Branch Circuit 

Cord 

in inches (mm)

 

 Number 

HP 

Load Amps 

Required (Amps) 

Length 

On       

Off

 

2905-04 

1/4 

6.0 

15 

8’ 

10” (254) 

3” (76)

 

2955-04 1/3  10.0  15 

8’  11” (279) 

4” (102)

 

2957-04 

1/3 

10.0 

15 

8’ 

7-1/2” (191) 

2-1/2” (64)

Motor, Switch, and Cord Specifications

GPM (LPM) AT TOTAL FEET (m)

 

  

 10 

15 

20 

25 

 

Model  (1.5m)  (3m)  (4.6m) (6.1m) (7.6m)

   

 

CAPACITY GALLONS(L)/HOUR

 

2905-04

 1,170 1,020  810  510 

 

 

(4,429)   (3,840)  (3,066)  (1,931) 

(0)

  2955-04 1,740 1,620 1,260  720 

60 

  2957-04 

(6,600)   (6,120)  (4,740)  (2,700) 

(240)

Содержание 2905-04

Страница 1: ... Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 800 468 7867 Español Paginas 12 16 2012 SIM860 07 20 12 OWNER S MANUAL Submersible Sump Pump NOTICE D UTILISATION Pompe de puisard submersible MANUAL DEL USUARIO Bomba sumergible de sumidero 5922 0109 5921 0109 2905 04 2955 04 2957 04 293 Wright Street D...

Страница 2: ... safety codes that apply 12 This equipment is only for use on 115 volt and is equipped with an approved 3 conductor cord and 3 prong grounding type plug Risk of electric shock Can shock burn or kill To reduce the risk of electric shock pull the plug before servicing Pump is supplied with a grounding conductor and grounding type attachment plug Be sure it is connected only to a properly grounded gr...

Страница 3: ...ion and requires a minimum 15 amp individual branch circuit Both the pump and switch are supplied with 3 wire cord sets with grounding type plugs The switch plug is inserted directly into the outlet and the pump plug inserts into the opposite end of switch plug Risk of electric shock Can shock burn or kill Pump is supplied with a grounding conductor and grounding type attachment plug To reduce the...

Страница 4: ...e basin with water and observing the pump s operation through one complete cycle Risk of flooding Can cause personal injury and or property damage Failure to make this operational check can lead to improper operation premature pump failure and flooding To Replace the Vertical Float Switch NOTICE The float must be able to complete its entire cycle without interference from any other object 1 Mount ...

Страница 5: ...ve float switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle in piping Float obstructed Remove obstruction Pump operates but Low line voltage If voltage under recommended minimum check size of wiring from main delivers little or no water switch on property If OK contact power company or hydro authority Worn or plugged impeller Replace pump Anti airlock v...

Страница 6: ...turn a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local...

Страница 7: ... et de l électricité en vigueur 12 Cette pompe ne fonctionne que sur le courant alternatif de 115 volts et elle est équipée d un cordon électrique approuvé à 3 conducteurs muni d une fiche à 3 broches dont une de mise à la terre Risque de secousses électriques Pouvant causer des brúlures voire la mort Pour réduire les risques de secousses électriques débrancher la fiche du cordon électrique de la ...

Страница 8: ...teurs eux mêmes munis d une fiche de mise à la terre La fiche de l interrupteur à flotteur se branche directement dans la prise de courant et la fiche de la pompe se branche à l arrière de la fiche de l interrupteur à flotteur Risque de secousses électriques Pouvant causer des brúlures voire la mort La pompe est livrée avec un conducteur et une fiche de mise à la terre Pour réduire les risques de ...

Страница 9: ...fonctionnement de la pompe sur un cycle complet Risque d inondation Peut causer le mauvais fonctionnement ou une panne prématurée de la pompe Ne pas procéder à cette vérification de fonctionnement risque de causer un mauvais fonctionnement et une panne prématurée de la pompe ainsi qu une inondation Pour remplacer un interrupteur à flotteur vertical AVIS Le flotteur doit pouvoir se déplacer sur tou...

Страница 10: ...e s arrête pas Interrupteur à flotteur défectueux Remplacer l interrupteur à flotteur Refoulement obstrué Déposer la pompe et la nettoyer ainsi que les tuyaux obstruction dans le tuyau Flotteur obstrué Enlever l obstruction La pompe fonctionne mais Tension de ligne basse Si la tension est inférieure à la tension minimum recommandée vérifier le ne débite pas d eau ou calibre des conducteurs côté in...

Страница 11: ...vec le service à la clientèle de SIMER Les pompes d eaux d égout qui ont été utilisées puis retirées présentent un risque de contamination En cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à l...

Страница 12: ...ado de una bomba de accionamiento eléctrico cumpla con todos los códigos de electricidad y seguridad que correspondan 12 Este equipo se debe usar solamente con 115 voltios y viene equipado con un cordón aprobado de 3 conductores y un enchufe de 3 clavijas con conexión a tierra Riesgo de choque eléctrico Puede provocar choque quemadura o muerte Para reducir el peligro de choque eléctrico desenchufe...

Страница 13: ... como el interruptor vienen con un juego de cordón trifilar y enchufe con puesta a tierra El enchufe del interruptor se inserta directamente en el tomacorriente y el enchufe de la bomba se inserta en el extremo opuesto del enchufe del interruptor Riesgo de choque eléctrico Puede provocar choque quemadura o muerte La bomba viene provista de un conductor de puesta a tierra y un enchufe de conexión a...

Страница 14: ... durante un ciclo completo Riesgo de inundación Puede provocar lesiones personales y o daños materiales El no realizar esta inspección de funcionamiento puede resultar en un funcionamiento inadecuado una falla prematura e inundación Cómo reemplazar el interruptor de flotador vertical AVISO El flotador debe poder completar todo su ciclo sin interferencia de objeto alguno 1 Monte el soporte en la ca...

Страница 15: ...fectuoso Reemplace el interruptor de flotador detiene con demasiada Descarga restringida Saque la bomba y limpie la bomba y la tubería frecuencia obstáculo en la tubería Flotador obstruido Elimine la obstrucción La bomba funciona pero Baja tensión de línea Si la tensión es inferior al mínimo recomendado verifique el tamaño de los descarga poco o nada cables desde el interruptor principal en la pro...

Страница 16: ...devuelva una bomba cloacal que se haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bo...

Отзывы: