Safety / Installation

2

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

GENERAL SAFETY

The pump motor is equipped with an automati-

cally resetting thermal protector

and may restart unexpectedly.

DO NOT plug in the pump while standing in water or on a wet
or damp surface.

DO NOT use in water where fish are present (oil in motor can
kill fish).

DO NOT pick up the pump by the power cord.

Protect the electrical cord from sharp objects, hot surfaces, oil,
and chemicals. Avoid kinking the cord.

Unplug the pump before servicing it or attempting to clean it.

Secure the discharge hose before starting the pump. An unse-
cured discharge hose may whip, which can cause personal
injury and property damage.

Keep the pump, base, and inlet screen free of debris and for-
eign objects. 

SPECIFICATIONS

Power supply required..........................................115V, 60 HZ.

Liquid Temp. Range........................................Max. 77°F (25°C)

Operation Position.........................................................Vertical

Individual Branch Circuit Required  ..............................15 Amp

Operating Depth

Beginning min...............................3/4"

(water level)

Ending max. ..................................1/4"

Discharge .........................................................1" NPT (25 mm)

DESCRIPTION

The submersible pump is designed for water removal from pool
covers in home swimming pool applications.  Unit is construct-
ed of hi-impact corrosion resistant plastic. Screened inlet and
base prevent large solids from entering pump and protect pool
cover.

NOTICE:

This unit is not designed for applications involving salt

water or brine! Use with salt water or brine will void warranty.

PERFORMANCE

INSTALLATION

Hazardous voltage. Can shock, burn or cause

death.

Do not use power cord to lift motor. Always use handle.

1. Pump should always stand upright on base when operating.

Do not suspend pump by means of discharge hose or
power cord. Keep pump inlet screen clear.

2. To install a garden hose, first install adapter provided with

pump.

NOTICE:

To keep friction as low as possible, hose must be

5/8" or larger. Keep hose as short as possible.

3. If, in your application, backflow is a problem when the

pump stops, prevent it by installing a 1” NPT check valve
in the pump discharge.

4. Power Supply: Pump is designed for 115V., 60 HZ. 

operation and requires an individual branch circuit of 
15 amperes or more capacity. It is supplied with a 3-wire
cord set with grounding-type, GFCI protected plug for use
in a 3-wire, grounded outlet. For safety, pump should
always be electrically grounded to a suitable electrical
ground such as a grounded water pipe or a properly
grounded metallic raceway or ground wire system. Do not
cut off the round grounding prong.

Risk of sudden starts. Can result in an elec-

trical shock or the pinching of hands or tools.

The pump

motor is equipped with automatic resetting thermal protec-
tor and may restart unexpectedly. Protector tripping is indi-
cation of motor overloading as a result of operating pump
at high pressure, excessively high or low voltage, inade-
quate wiring, incorrect motor connections, or a defective
motor or pump.

GPH (LPH) AT TOTAL FEET (M)

3'

5'

10'

15'

18'

20'

22'

(0.91)

(1.52)

(3.05)

(4.57)

(5.49)

(6.09)

(6.70)

1600 gal 1524 gal 1260 gal 924 gal

648 gal

372 gal

0 gal

(6 057 L) (5 769 L) (4 770 L) (3 498 L) (2 453 L) (1 408 L)

(0 L)

IMPORTANT SAFETY

INSTRUCTIONS

When installing and using this electrical equipment,
basic safety precautions should always be followed,
including the following:

READ AND FOLLOW

ALL INSTRUCTIONS

To reduce the risk of injury, do not

permit children to use this product

unless they are

closely supervised at all times.

Risk of Electric Shock.

Connect only

to a properly-grounded, grounding type receptacle.
The pump requires 115 volt, single phase current.
The pump is protected by a ground-fault circuit
interrupter (GFCI) built into the plug. Do not modify
the cord, plug, or GFCI.

Do not bury cord. Locate cord to minimize abuse
from lawn mowers, hedge trimmers, and other
equipment.

To reduce the risk of electric shock,

replace damaged cord immediately.

To reduce the risk of electric shock,

do

not use an extension cord to connect the unit to the
electrical supply; provide a properly located outlet.

SAVE THESE 

INSTRUCTIONS

Содержание 2115

Страница 1: ...tance Call 1 800 468 7867 English Pages 2 5 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Français Pages 6 9 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 468 7867 Español Paginas 10 13 2007 SIM822 Rev 12 10 07 MODEL...

Страница 2: ... application backflow is a problem when the pump stops prevent it by installing a 1 NPT check valve in the pump discharge 4 Power Supply Pump is designed for 115V 60 HZ operation and requires an individual branch circuit of 15 amperes or more capacity It is supplied with a 3 wire cord set with grounding type GFCI protected plug for use in a 3 wire grounded outlet For safety pump should always be e...

Страница 3: ...he motor will restart NOTICE If the overload protector stops the pump repeated ly disconnect the power from the pump and check it to find the problem Low voltage clogged impeller too much back pressure in the discharge hose as when pumping through 50 15 M of coiled hose or extended running of pump with no load can all cause overheating 2 The water being pumped cools the motor allowing the pump to ...

Страница 4: ... motor fails replace entire pump Not Illustrated SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Pump won t Blown fuse If blown replace with fuse of proper size start or run Low line voltage If voltage under recommended minimum check size of wiring from main switch on property If OK contact power company Defective motor Replace pump Impeller Remove base and screen locate source of binding Pump operates...

Страница 5: ... including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to SIMER as soon as possi ble after the discovery of any alleged defect SIMER will subsequently take correcti...

Страница 6: ... que possible 3 Si en fonction de l utilisation le refoulement représente un problème lorsque la pompe s arrête poser un clapet antire tour de 1 pouce NPT côté refoulement de la pompe 4 Source d alimentation La pompe est conçue pour du 115V et 60HZ et requiert un circuit de dérivation individuel de 15 ampères ou plus Elle est fournie avec un cordon trifilaire et une fiche de type mise à la terre e...

Страница 7: ...on répétitive débrancher la pompe et déterminer le problème Une basse tension un impulseur bouché une contre pression trop importante dans le tuyau de refoulement comme pomper de l eau dans un tuyau enroulé ayant jusqu à 50 pieds 15 mètres ou un fonctionnement prolongé à vide de la pompe causera une surchauffe 2 L eau pompée refroidit le moteur ce qui permet à la pompe de fonctionner continuelleme...

Страница 8: ...té Le moteur est défectueux Remplacer la pompe Roue hélice Retirer la base et le filtre repérer la source de l obstruction La pompe La tension est faible Appeler la compagnie d électricité fonctionne mais Quelque chose obstrue Nettoyer la roue hélice elle déverse peu la roue hélice ou pas d eau Tuyau d arrosage de petit Utiliser un tuyau souple de 1 pouce ou un tuyau d arrosage de plus grand diamè...

Страница 9: ...ausées par la corrosion la rouille ou autre corps étranger dans le système ou à des produits ayant fonctionné à des pressions dépassant la limite maximale recommandée Les demandes de service en vertu de la présente garantie seront faites en retournant le produit défectueux au détaillant ou à SIMER dès la dé couverte de tout défaut allégué SIMER prendra alors les mesures correctives aussi rapidemen...

Страница 10: ...roflujo es un problema cuando la bomba se detiene evítelo instalando una válvula de reten ción de 1 NPT en la descarga de la bomba 4 Fuente de alimentación La bomba está diseñada para operar a 115V y 60 Hz y requiere un ramal individual de 15 amperes o más de capacidad Se suministra con un juego de cordón de 3 alambres con enchufe tipo conexión a tierra protegido por un disyuntor para ser utilizad...

Страница 11: ...blema Tensiones bajas impulsores bloqueados demasiada presión en la manguera de descarga como en los casos en que se bombea a través de 50 pies 15 metros de manguera enredada o una operación prolongada de la bomba sin carga pueden causar recalentamiento 2 El agua que se bombea enfría el motor lo que permite que la bomba continúe funcionando a cualquier profundidad de agua por encima de 1 4 de pulg...

Страница 12: ...a compañía eléctrica Motor defectuoso Reemplace la bomba Impulsor Saque la base y el filtro ubique la fuente de fijación La bomba Bajo voltaje de línea Llame a la compañía de electricidad funcionapero Objeto atascado en el rodete Limpie el impulsor no suministra Manguera de jardín de Use una manguera de jardín de mayor diámetro o un tubo flexible de 1 agua o muy diámetro chico o línea de Deseche e...

Страница 13: ... incluyendo pero no limitado a fallas operacionales causadas por corrosión oxidación u otros elementos extraños en el sistema o funcionamiento a presión por encima del máximo recomendado Los pedidos de servicio bajo los términos de esta garantía serán efectuados mediante la devolución del producto defectuoso al Vendedor o a SIMER tan pronto como sea posible después de localizado cualquier supuesto...

Страница 14: ...14 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 ...

Страница 15: ...15 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 ...

Страница 16: ......

Отзывы: