Supplied By www.heating spares.co Tel. 0161 620 6677
3
40 Ci EI
50 Ci EI
60 Ci EI
80 Ci EI
Burner
Injector
1
ø mm
3.25
3.25
3.55
4.10
Max. gas consumpt.
m
3
/h
1,38
1,69
2,05
2,75
System Press
min
bar
0.12
max
bar
3
Adjustable Flow Temp
Pump mode min
°C
50 on - 60 off
Pump mode max °C
72 on - 84 off
Safety stat
°C
105
Re-Start Delay
Seconds
180
Anti-Inertia Temp.
°C
90 off - 95 on
Max. working temp.
°C
84
Boiler pressure drop
∆
t 11°C
mbar
100
150
220
330
Electricity Supply
230V/50Hz
Internal Fuse
F 2A
Power Consumption
W
55
55
60
65
Weight
kg
46
46
46
57
TABLE 4 - General specifications
TABLE 3d - Nominal boiler ratings (2 minutes after lighting) for Superior 80 Ci EI
MODE
OUTPUT
INPUT (N.C.V.)
INPUT (G.C.V.)
BURNER PRESSURE
kW
Btu/h
kW
kW
Btu/h
mbar
inwg
CENTRAL HEATING RANGE
17.6
59,900
19.9
22.1
75,200
8.5
3.4
18.2
62,000
20.5
22.8
77,500
9.0
3.6
18.8
64,000
21.2
23.5
80,100
9.6
3.9
19.3
65,700
21.7
24.1
82,000
10.2
4.1
19.9
67,800
22.3
24.8
84,300
10.8
4.3
20.5
69,800
22.9
25.4
86,600
11.4
4.6
21.1
71,900
23.6
26.2
89,200
12.2
4.9
21.7
73,900
24.2
26.9
91,500
12.8
5.1
22.2
75,600
24.7
27.4
93,400
13.4
5.4
22.8
77,600
25.3
28.1
95,600
14.0
5.6
X
*
23.4
79,700
26.0
28.9
98,300
14.7
5.9
*Factory setting
Содержание SUPERIOR Ci EI
Страница 2: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 4: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 11: ...Supplied By www heating spares co Tel 0161 620 6677 7 TYPICAL SYSTEM DESIGN FULLY PUMPED OPEN VENTED Fig 5 ...
Страница 30: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 31: ...Supplied By www heating spares co Tel 0161 620 6677 ...