USER INSTRUCTIONS
VERY IMPORTANT!
PLEASE MAKE SURE YOUR LOG BOOK ENCLOSED IS FILLED IN CORRECTLY.
ALL CORGI REGISTERED INSTALLERS CARRY A CORGI ID CARD.
BOTH SHOULD BE RECORDED IN YOUR CENTRAL HEATING LOG BOOK.
YOU CAN CHECK YOUR INSTALLER IS CORGI REGISTERED
BY CALLING ON 01256 372300
GAS SAFETY [INSTALLATION AND USE] REGULATIONS [as
amended]. It is the law that a registered person, in accor-
dance with the above regulations, installs all gas appliances.
Failure to install appliances correctly could lead to prosecu-
tion. It is in your own interest, and that of safety, to ensure
that the law is complied with.
It is essential that the appliance be correctly earthed.
An electricity supply of 230 V~ 50 Hz fused at 3 A is
required.
Read these instructions carefully before attempting to oper-
ate the appliance.
1.1
INTRODUCTION
The Sime “
Superior Ci EI
” are a range of wall mounted cast
iron boilers. They utilise a fully automatic ignition system
together with electronic temperature control. The combus-
tion system is fan assisted and uses a concentric flue and air
duct that can exit the boiler to either side or to the rear, end-
ing in a small balanced flue terminal on the outside wall.
The appliance is suitable for use with natural gas.
1.2
APPLIANCE OPERATION
The installation engineer will have set the range rated appli-
ance to the correct heating requirement for the property.
There should be no need to adjust the boiler control once it
has been set unless the temperature set point needs to be
increased or decreased. The thermostat knob will adjust the
set point temperature of the electronic controls in the appli-
ance. Turning clockwise increases the set point.
A demand for heat from the external controls will:
– check the air pressure switch,
– start the fan,
– confirm correct air flow through the appliance,
– start the spark generator,
– open the gas valve,
– ignite and prove the flame,
– monitor the appliance flow temperature, switching the
appliance on and off as necessary.
– should the appliance fail to light, the lockout button will illu-
minate.
1.3
OPERATING INSTRUCTIONS
1.3.1
To light the appliance
– Turn on the electrical supply and set all external controls
to on.
– Turn the boiler control to maximum and check the pump is
operating correctly and water is circulating.
– After a short period the ignition lockout indicator will be illu-
minated, after a 10 second wait depress the lockout button
to reset the ignition sequence. Turn off the boiler control.
OPERATING INSTRUCTIONS FOR THE USER
IGNITION AND
TEMPERATURE CONTROL
LOCK-OUT BUTTON
OVERHEAT WARNING LAMP
APPLIANCE CONTROLS
Содержание SUPERIOR Ci EI
Страница 2: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 4: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 11: ...Supplied By www heating spares co Tel 0161 620 6677 7 TYPICAL SYSTEM DESIGN FULLY PUMPED OPEN VENTED Fig 5 ...
Страница 30: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 31: ...Supplied By www heating spares co Tel 0161 620 6677 ...