74
1.3
USE AND MAINTENANCE
1.3.1
PRELIMINARY
IGNITION CHECKS
Before the use of the boiler, it is necessary
to follow the following instructions:
– The installation where the boiler is con-
nected to, should be preferably with an
open expansion tank (fig. 10).
– The tube, which connects the boiler to
the expansion tank, should have an ade-
quate diameter according to the norms
in force.
– The heating pump should always be run-
ning during the operation of the boiler.
– A possible ambient thermostat should
never interrupt the pump operation.
– If the installation is equipped with a 3 or
4 ways mixing valve, it should always be
placed in the opening position toward
the installation.
– Be assure that the draught regulator wor-
ks regularly and that there aren’t impedi-
ments, which block the automatic opera-
tion of the air gate damper.
1.3.2
CLEANING
The cleaning should be carried out with a
certain frequency providing besides the cle-
aning of the smoke passages, also the cle-
aning of the ash box, removing the ashes,
which are contained in the collection basin.
Use a proper pull-through for the cleaning
of the smoke passages (fig. 11).
1.3.3
MAINTENANCE
Do not perform any maintenance work, di-
smantling or removal of parts without pro-
perly emptying the boiler first.
The boiler must not be emptied when the
water is hot.
CAUTION: The safety valve on the system
must be inspected by technically qualified
personnel in accordance with the laws of
the country of distribution and instructions
for use of the safety valve. If the system is
completely emptied and remains unused
for some time, the safety valve must be in-
spected before it is used again.If the safety
valve should malfunction and cannot be re-
calibrated, replace it with a new 1/2” valve
calibrated to 3 BAR and conforming with
Directive PED 2014/68/UE.
Fig. 10
Closed expansion tank system with heat exchanger and optional thermostat valve
Fig. 9/a
LE GEN D
VE Expansion tank
VS System safety valve 3 BAR - 1/2”
VM Mixing valve
VR Check valve
PI System pump
IR Heating system
VT Thermostat valve
SC Safety exchanger
F Filter
CAUTION: The safety exchanger is supplied in an
optional kit code
8105200
.
Temperature of the water supplied to the safety heat
exchanger: 10°C.
Pressure of the water supplied to the safety heat
exchanger: 2 bar.