24
DESCRIPTION
Murelle Revolution 30
NOZZLES - GAS
Number of nozzles
No.
1
Nozzle diameter (G20-G31)
mm
5.3
Gas consumption at Max/Min flow rate (G20)
m
3
/h
2.96 / 0.42
Gas consumption at Max/Min flow rate (G31)
Kg/h
2.17 / 0.31
Gas supply pressure (G20/G31)
mbar
20 / 37
kPa
2 / 3.7
TEMPERATURE - PRESSURE
Max operating temperature (T max)
°C
75
Heating adjustment range
°C
20÷75
Domestic hot water adjustment range
°C
10÷60
Max operating pressure (PMS)
bar
2.5
kPa
250
Water content in boiler
l
4.65
Lower Heat Output (Hi)
G20 Hi.
9.45 kW/m
3
(15°C, 1013 mbar) - G31 Hi. 12.87 kW/kg (15°C, 1013 mbar)
4.6.2
Heat pump
DESCRIPTION
Murelle Revolution 30
Model
HYSIMO104M
HEATING PERFORMANCE
Heating water maximum temperature
°C
50
Heating water maximum pressure (DHWMP)
bar
3
Seasonal efficiency
%
155
Energy efficiency class of central heating
A++
Nominal power (Q
n
max)
kW
4,0
Refrigerant
R-410A
Refrigerant load
kg
1,15
ELECTRICAL SPECIFICATIONS
Power supply voltage
V
230
Frequency
Hz
50
Nominal electrical power
W
1334
Maximum electrical power
1650
Nominal absorption
A
6,0
Maximum absorption
6,8
Protection rating against humidity and water pene-
tration
IP
X5D
"CONTO ENERGIA TERMICO 2.0" RENEWABLE THERMAL ENERGY INCENTIVE
COP
4,45 (*)
(*) Value obtained with:
- (*) External temperature = + 7°C
- Heat pump air input/output temperature = 30/35°C.