PARAMETER SETTING
To use the remote control (CR)
as room reference for a zone,
set:
PAR 7 = 1
Set the opening time of the zone
valve VZ:
PAR 33 = “OPENING TIME”
R
M
SE
CT2
TA1
SE
CT1
TA2
VZ1
VZ2
ZONA
GIORNO
(70
°
C)
ZONA
NOTTE
(50
°
C)
DURING NIGHT TIME THE BOILER
USES A LOWER OUTPUT TEMPE-
RATURE IF DIFFERENT TIMES HAVE
BEEN SET FOR DAY AND NIGHT
AREAS:
-
with external sensor,
set the cli-
matic curve of the day zone 1 with
PAR 25 and the night zone at PAR
26.
-
without external sensor,
gain
access to setting the day zone 1
by pressing the key
and chan-
ge the value with the keys
and
. Gain access to setting
the night zone by pressing the key
twice and changing the value
with the keys
and
.
SI
R
M
SE
TA1
TA2
TA2
SE
TA
P2
RL
RL1
RL2
P1
P
CR
CR
PARAMETER SETTING
To use the remote control
(CR) as room reference for a
zone, set:
PAR 7 = 1
5
BASIC SYSTEM
MULTI-ZONE SYSTEM WITH VALVE, ROOM THERMOSTAT, REMOTE CONTROL CR 73 (Code 8092226)
AND EXTERNAL SENSOR (Code 8094101)
6
BASIC SYSTEM
MULTI-ZONE SYSTEM WITH PUMP, ROOM THERMOSTAT, REMOTE CONTROL CR 73 (Code 8092226)
AND EXTERNAL SENSOR (Code 8094101)
7
SYSTEM WITH DOUBLE TEMPERATURE OUTPUT
MULTI-ZONE SYSTEM WITH VALVE, CHRONOTHERMOSTAT AND EXTERNAL SENSOR (Code 8094101)
DAY
ZONE
(70°C)
NIGHT
ZONE
(50°C)