70
ES
PT
GB
Models
25 BF
30 BF
35 BF
12 BFT
20 BFT
25 BFT
30 BFT
35 BFT
Heat output
Nominal (80-60°C)
kW
23.9
28.9
34.1
11.7
19.0
23.9
28.9
34.1
Nominal (50-30°C)
kW
26.2
31.6
37.2
12.8
20.9
26.2
31.6
37.2
Reduced G20 (80-60°C)
kW
4.7
5.9
7.9
2.8
4.2
4.7
5.9
7.9
Reduced G20 (50-30°C)
kW
5.4
6.6
8.8
3.2
4.8
5.4
6.6
8.8
Reduced G31 (80-60°C)
kW
7.5
7.6
8.7
7.5
7.5
7.5
7.6
8.7
Reduced G31 (50-30°C)
kW
8.5
8.5
9.6
8.5
8.5
8.5
8.5
9.6
Heat input
Nominal
kW
24.5
29.5
34.8
12.0
19.5
24.5
29.5
34.8
Reduced G20/G31
kW
5.0/8.0
6.2/8.0
8.2/9.0
3.0/8.0
4.5/8.0
5.0/8.0
6.2/8.0
8.2/9.0
Max/min useful yield (80-60°C)
%
94/97.5
95/98
96/98
94/97.5
94/97.5
94/97.5
95/98
96/98
Max/min useful yield (50-30°C)
%
107/107
107/107 107/107 107/107 107/107 107/107 107/107
107/107
Useful yield at 30% of the load (50-30°C)
%
107
107
107
107
107
107
107
107
Termal efficiency (CEE 92/42 directive)
HHHH
HHHH
HHHH
HHHH
HHHH
HHHH
HHHH
HHHH
Losses after shutdown to 50°C (EN 483)
W
85
90
95
80
85
85
90
95
Supply voltage
V-Hz
230-50
230-50
230-50
230-50
230-50
230-50
230-50
230-50
Adsorbed power consumption
W
125
130
140
115
125
130
135
145
Electrical protection grade
IP
X4D
X4D
X4D
X4D
X4D
X4D
X4D
X4D
C.H. setting range
°C
20/80
20/80
20/80
20/80
20/80
20/80
20/80
20/80
Water content boiler
l
4.9
5.5
6.0
4.4
5.0
5.0
5.6
6.1
Maximum water head
bar
3
3
3
3
3
3
3
3
Maximum temperature
°C
85
85
85
85
85
85
85
85
Capacity of the heating expansion vessel
l
8
10
10
8
8
8
10
10
Pressure of the heating expansion vessel
bar
1
1
1
1
1
1
1
1
D.H.W. setting range
°C
30/60
30/60
30/60
--
--
--
--
--
D.H.W. flow rate (EN 625)
l/min
11.1
13.6
16.1
--
--
--
--
--
Continuous D.H.W. flow rate
∆
t 30°C
l/min
11.3
13.8
16.3
--
--
--
--
--
Minimum D.H.W. flow rate
l/min
2
2
2
--
--
--
--
--
D.H.W. pressure min/max
bar
0.2/7.0
0.2/7.0
0.2/7.0
--
--
--
--
--
D.H.W. pressure min. nom. power
bar
0.5
0.65
0.8
--
--
--
--
--
Exhaust fumes temperature at max flow rate (80-60°C)
°C
70
70
70
70
70
70
70
70
Exhaust fumes temperature at min. flow rate (80-60°C)
°C
65
65
65
65
65
65
65
65
Exhaust fumes temperature at max flow rate (50-30°C)
°C
40
40
40
40
40
40
40
40
Exhaust fumes temperature at min. flow rate (50-30°C)
°C
35
35
35
35
35
35
35
35
Smokes flow min/max
kg/h
9/42
11/50
14/60
5/21
8/33
9/42
11/50
14/60
CO
2
at max/min flow rate G20
%
9.0/9.0
9.0/9.0
9.0/9.0
9.0/9.0
9.0/9.0
9.0/9.0
9.0/9.0
9.0/9.0
CO
2
at max/min flow rate G31
%
10.0/10.0 10.0/10.0 10.0/10.0 10.0/10.0 10.0/10.0 10.0/10.0 10.0/10.0 10.0/10.0
CE certification
n°
1312BS5039
Category
II2H3P
Type
B23P-53P/C13-33-43-53-83
NOx emission class
5 (< 30 mg/kWh)
Weight when empty
kg
43
57
69
31
42
42
56
68
Main burner nozzle
Quantity nozzles
n°
1
1
1
1
1
1
1
1
G20/G31 nozzle diameter
ø
5.0/3.7
7.0/5.0
8.5/5.2
4.0/3.1
5.0/3.7
5.0/3.7
7.0/5.0
8.5/5.2
Consumption at maximum/minimum flow rate
Maximum G20
m
3
/h
2.59
3.12
3.68
1.27
2.06
2.59
3.12
3.68
Minimum G20
m
3
/h
0.53
0.66
0.87
0.32
0.48
0.53
0.66
0.87
Maximum G31
kg/h
1.90
2.29
2.70
0.93
1.51
1.90
2.29
2.70
Minimum G31
kg/h
0.62
0.62
0.70
0.62
0.62
0.62
0.62
0.70
Gas supply pressure
G20/G31
mbar
20/37
20/37
20/37
20/37
20/37
20/37
20/37
20/37
1.3
TECHNICAL FEATURES