6 BOILER 

REGISTRATION

Owner

 

-name

Installation Address 

-Street

City

PC

State

Installation Phone Number

Contact and Phone Number

IMPORTANT INFORMATION

Please read before Installation. Fill in and retain with the boiler for future use.

LOG BOOK - Installation, Commissioning and Service

1. Installation Details

Sime Product 

- Model

Serial Number

refer to data plate

Gas Type

Natural Gas  

LPG  

Internal  

External  

Gas pressure
Settings

Central Heating.
Adjusted output 
setting

Max

Pa

kW

The System pipes MUST BE FLUSHED before the connecting this boiler

New  

Existing  

System FLUSHED before 
installation of boiler

Yes  

Water treatment           No  

      Yes  

Product

Qty Used Litres

System Volume                       Litres

Dilution rate

Litres per 100 litres

Installer Company

Company Address

City

PC

State

Installer Name

PIC Licence No.

Commissioning completed     

Date;-            /            /20__

by

Hand Over completed              

Date;-            /            /20__

to

Содержание Murelle Green Planet 110 HE I

Страница 1: ...r and Service Instructions AUS WARNING The installation of this product must be carried out only by authorised personnel to the requirements of Australian Standard AS 5601 local authority gas elec tri...

Страница 2: ...at the base Be physically capable Use personal protective equipment as appropriate e g gloves safety footwear During all manoeuvres and handling actions every attempt should be made to ensure the fol...

Страница 3: ...that the flue pipe for the outlet of the products of the combustion is unobstructed and has been pro perly installed Make sure that any shutoff valves are open Make sure that the system is charged wit...

Страница 4: ...2004 108 CE 2006 95 CE and 92 42 CE For optimum installation and operation always follow the instructions provided in this manual 1 DESCRIPTION OF THE BOILER 200 120 115 70 120 235 M R R3 S3 G 281 15...

Страница 5: ...246 306 199 120 139 74 S3 R3 R M S1 G 600 Fig 1 a FIXTURES R Heating return G 1 1 2 UNI ISO 228 1 R3 D H W tank return G 1 1 2 UNI ISO 228 1 M Heating flow G 1 1 2 UNI ISO 228 1 G Gas connection G 3 4...

Страница 6: ...ontinuous D H W flow rate t 30 C l min Minimum D H W flow rate l min D H W pressure min max bar D H W pressure min nom power bar Exhaust fumes temperature at max flow rate 80 60 C C 86 2 Exhaust fumes...

Страница 7: ...Heating return sensor SR 4 Fan 5 Heating flow sensor SM 6 Safety thermostat 95 C 7 Exhaust probe SF 8 Primary heat exchanger 11 Water pressure transducer 12 Auto air vent 13 Pump 14 Drain vent 17 5 B...

Страница 8: ...ENTS fig 3 KEY 1 Control panel 2 Fan 3 Ignition electrode 4 Primary heat exchanger 5 Ignition transformer 6 Exhaust probe SF 7 Auto Air Vent 8 Heating return sensor SR 9 Heating flow sensor SM 10 Safe...

Страница 9: ...system must have the following installation parameters modified When the boiler is used in cascade PAR 1 of each boiler in the cascade must be reset as follows PAR 1 8 if boiler is NATURAL GAS G20 PAR...

Страница 10: ...nated Master boiler to 0 On the Master boiler press any key to wake up the display Then press simultaneously the and the buttons for 5 seconds until the display is as shown Then press again simultaneo...

Страница 11: ...acteristic impedance 100 GND GND GND GND GND GND INSTALLER PARAMETERS SETTING PAR 15 CASCADE ADDRESS Disabled 0 Master 1 7 Slave N B Ensure that each slave is numbered separately ATTENTION CONNECT UP...

Страница 12: ...slave must be assigned with a different number PAR 17 MODBUS CONFIGURATION Disabled 1 30 Factory value 25 See Tab PAR 17 INST ATENTION Switch off and restart the boiler after setting PAR 17 1 1200 8...

Страница 13: ...01 Boiler Hydraulic Parameter Par2 I R 0 199 Request CH zone 1 Enable DHW preparation Not used State CH zone 1 State preparation DHW State presence flame State presence alarm Setpoint CH zone 1 If you...

Страница 14: ...RS 485 connection to the INSOL MIXED ZONE fig 4 e The RS 485 board can be connected to optional INSOL kit code 8092254 or MIXED ZONE code 8092252 Both require the board housing kit code 8092236 Carry...

Страница 15: ...2 Filter on the gas pipe The gas valve is supplied ex factory with an inlet filter which however is not adequate to entrap all the impurities in the gas or in gas main pipes To prevent malfunctioning...

Страница 16: ...the correct operation of the appliance set the installer para meter PAR 9 as indicated in TABLES 3 3 a see point 3 3 to access the instal ler parameters B type Fig 6 G N I N R A W When load loss of t...

Страница 17: ...ting CO2 at the maximum and minimum capacity as specified in point 4 2 2 TABLE 2 Load loss PAR 9 mm H2O long chimneys 0 4 0 4 8 1 8 12 2 12 16 3 16 20 4 20 24 5 24 28 6 28 32 7 32 36 8 36 40 9 40 42 1...

Страница 18: ...length PAR 9 exhaust m long chimneys 0 1 0 6 1 0 2 0 7 2 0 3 0 8 3 0 4 0 9 4 0 5 0 10 HORIZONTAL EXHAUST To ensure correct operation of the appliance do as follows set the installer parameter PAR 9 a...

Страница 19: ...J h input 150 150 Other appliances up to 50 MJ h input 500 500 Appliances over 50 MJ h input and up to 150 MJ h input 1000 1000 n Appliances over 150 MJ h input 1500 1500 Unless appliance is certified...

Страница 20: ...lu ded in the packaging NOTE Reset parameter 10 to 2 PAR 10 2 2 6 3 Remote control CR 73 connection optional The boiler is designed for connection to a remote control unit supplied on request code 809...

Страница 21: ...2 environment thermostat SB Sensor tank L 2000 optional CR Remote control CR73 optional SE External sensor optional OP Programming clock optional AR Remote alarm VZ Zone valve AUX Auxiliary connection...

Страница 22: ...code 8092228 or digital clock code 8092229 to program heating single zone only Fig 12 3 KEYS RESERVED FOR THE INSTALLER access to INST and OEM parameters PC CONNECTION To be used only with the SIME pr...

Страница 23: ...azione corrente di ionizzazione in A 17 Visualizzazione portata sanitaria flussimetro es 18 l min e 0 3 l min o stato flussostato rispettivamente ON e OFF 12 Visualizzazione numero totale delle anomal...

Страница 24: ...e codice errore ultima anomalia 61 Visualizzazione codice errore penultima anomalia 70 Codice di warning 90 Versione software presente su RS 485 es versione 01 91 Versione software presente su schedin...

Страница 25: ...x100 0 1 from 0 1 to 19 9 0 0 1 from 20 to 81 9 Long chimneys 0 20 1 0 10 Remote control option setting 1 CR 73 1 2 CR 53 3 RVS 43 143 4 RVS 46 530 5 RVS 61 843 11 Correction values external sensor 5...

Страница 26: ...lt values can be reset by setting PAR 49 1 and the PAR 1 and PAR 2 as specified at point 3 3 1 CODE DESCRIPTION E0 Operation in power reduction t between supply and return more than 40 C E1 External s...

Страница 27: ...control CR 73 thermal regulator RVS connected to a mana gement card of a mixed zone MIXED ZONE code 8092234 card solar INSOL code 8092235 and to board RS 485 for managing up to 8 boilers in cascade or...

Страница 28: ...rt up again 3 8 HEAD AVAILABLE TO SYSTEM fig 14 Residual head for the heating system is shown as a function of rate of flow in the graph in fig 14 Portata l h mbar 0 PREVALENZA 400 800 1200 778 748 73...

Страница 29: ...as valve 2 Condensation drain trap 3 Heating return sensor SR 4 Fan 5 Heating Flow Sensor SM 6 Safety thermostat 95 C 7 Exhaust sensor SF 8 Primary heat exchanger 11 Water pressure transducer 12 Auto...

Страница 30: ...all other gas ap pliances in the property working Combustion check 2 Connect the ue gas analyser to the ue gas sampling point as shown in the diagram Procedure for checking the combu stion Operate th...

Страница 31: ...he fuel to propane G31 it is necessary to set SET 15 by pressing the key The standard display will automatically return after 10 seconds The table below shows the SET settings to enter when the type o...

Страница 32: ...t be done During the routine service the condensa te drain can be checked by carefully pou ring water into the combustion chamber while the burner is removed Should the boiler not be used for long per...

Страница 33: ...d by means of the installer parameter PAR 43 0 Not activated function 1 Curve setting A 2 Curve setting B 3 Curve setting A B The turning off of the function happens clicking on the button OFF return...

Страница 34: ...circuit is intact check that there are no leaks HIGH WATER PRESSURE ERROR ALARM 03 fig 23 b If the pressure detected by the tran sducer is more than 4 8 bar the boi ler stops and the display shows er...

Страница 35: ...tected the boiler will make two further attempts If circu lation is not detected it will stop and display ALL09 Note circulation is detected by a small rise in system pressure at the boiler transducer...

Страница 36: ...Fig 23 t SOLAR COLLECTOR SENSOR ERROR S1 ALL 24 fig 23 18 When the solar probe is open or short circuited on the display the anomaly ALL 24 appears During this anomaly the boiler continues to function...

Страница 37: ...e boiler stop and the display shows ALL 33 The boiler re start when the communi cation is restored or set PAR 16 Fig 23 j RS 485 COMUNICATION ERROR IN CASCADE MODE ALL 34 fig 23 x When il PAR 15 is di...

Страница 38: ...not play with the appliance LIGHTING AND OPERATION BOILER IGNITION fig 24 The first ignition of the boiler must be carried out by qualified technical person nel Successively if it is necessary to star...

Страница 39: ...d if low temperatures are expected to completely empty the hydraulic circuits to avoid pipes being damaged by frost ERRORS AND SOLUTIONS When there is a functioning error the display shows an alarm an...

Страница 40: ...lashes on the display During such error the boiler conti nues normal functioning Fig 27 f ALL 20 Request assistance from quali fied technical personnel ALL 21 Request assistance from quali fied techni...

Страница 41: ...ial Number refer to data plate Gas Type Natural Gas LPG Internal External Gas pressure Settings Central Heating Adjusted output setting Max Pa kW The System pipes MUST BE FLUSHED before the connecting...

Страница 42: ...water Check gas ame is the correct colour and for gas and water leaks as the system heats up 12 Check that heat is going to all radiators through the manual or thermostatic rst and return via the lock...

Страница 43: ...ettings 3 How to turn the heating system off in summer and on for winter 4 Where all the major items are their functions and how to check and turn them on or off Simple fault resolution i e power on 5...

Страница 44: ...vice technician Name PIC Licence No Service Company Contact phone number Work Completed Note Service 3 year 5 Date Service technician Name PIC Licence No Service Company Contact phone number Work Comp...

Страница 45: ...Contact phone number Work Completed Note Service 6 year 11 Date Service technician Name PIC Licence No Service Company Contact phone number Work Completed Note Service 7 year 13 Date Service technici...

Страница 46: ...9 on each boiler must be set according to the calculated head loss tables on g 6 7 and 8 Boiler 1 Boiler 2 Boiler 3 Boiler 4 Boiler 5 Boiler 6 Calculated head loss Set value of PAR 9 PAR 1 see sec on...

Страница 47: ...with gas isolated to ensure boiler fails safe Y N Turn on gas supply to boiler and isolate main burner disconnect gas valve and ensure boiler goes to lockout Y N Reset boiler lockout and retry ensuri...