G
M
R
4
Mount the series of three-way drain cocks
and the system delivery/gas cocks to the
relative collectors and connect the tubes to
the fittings of the boiler using the respective
gaskets.
CAUTION: Before assembling the three-
way drain cocks, reposition the ball regula-
tor shaft as indicated in the figure.
M C.H.
flow
R C.H.
return
G Gas
ORIENTAMENTO ALBERO
REGOLAZIONE SFERA
CURVA DI
SCARICO
NIPPLO 3/4"
POSIZIONE MONTAGGIO LEVA
COLLETTORE
DI RITORNO
LEVER ASSEMBLY POSITION
SHAFT DIRECTION
BALL ADJUSTMENT
RETURN
COLLECTOR
DRAIN
CURVE
NIPPLE 3/4”
21