INTRODUCTION
The Sime
“FORMAT C”
are wall mounted, fan assisted bal-
anced flue combination boilers.
The appliance is supplied suitable for use with natural gas,
LPG and provide central heating and instantaneous produc-
tion of D.H.W. Heat output is varied according to demand by
the modulating gas control on both D.H.W. and C.H.
The appliance is supplied with a telescopic air/flue duct suit-
able for wall thicknesses up to 635 mm (25 in) although
extension duct kits are available and may be used up to a total
flue lenght of 3.4 m (133
7
/
8
in) for
“FORMAT 80 C”
model
and 3.0 m (118 in) for
“FORMAT 100 C”
model.
The combined flue and air duct can exit the boiler from either
side or from the rear of the appliance. A vertical extension and
additional flue elbow may be fitted. If required, the boilers can
also be fitted with a separate flues kit (see section 3 for details).
The boiler is designed for use with sealed primary water sys-
tems and is supplied fully assembled and equipped with com-
plete valve packs.
If the wall thickness is less than 0.5 m (19 in) the appliance
can be installed from inside the room without access to the
external wall although a wall liner is required.
This is available as an optional extra, and full details are given
in section 3.
The boiler can be used with a 240V room thermostat (class
II according to EN 60730.1).This booklet provides instructions
for the following boiler models:
–
“FORMAT 80 C”
with electronic ignition and modulation,
mechanical time clock built-in ex factory.
–
“FORMAT 100 C”
with electronic ignition and modulation,
mechanical time clock built-in ex factory.
1
1
TECHNICAL FEATURES AND DIMENSIONS
TABLE 2 - Minimum clearances
ABOVE THE APPLIANCE CASING
225 mm
9 in
AT THE R.H.S.
100 mm
4 in
AT THE L.H.S.
100 mm
4 in
BELOW THE APPLIANCE CASING
200 mm
8 in
IN FRONT OF THE APPLIANCE
350 mm
14 in
TABLE 1 - Connections
R
C.H. return
22 mm
Compression
M C.H. flow
22 mm
Compression
G
Gas connection
1/2 in
Bsp
E
Cold water
15 mm
Compression
U
Hot water
15 mm
Compression
1.2
DIMENSIONAL DETAILS
80 C
100 C
L mm
400
450
K mm
180
205
Fig. 1