104
4.1
D.H.W. TANK UNIT
The. enamelled. D.H.W..tank. comes. with.
a.magnesium.anode.to.protect.the.boiler.
and.an.inspection.flange.for.checking.and.
cleaning..
The magnesium anode must
be checked annually and replaced if it
is worn.
It.is.advisable.to.place.a.sluice.
gate. at. the. entrance. of. the. D.H.W.. tank.
unit.which,.apart.from.the.total.closure,.
allows.the.regulation.of.the.supply.capa-
city.
When the boiler does not produce hot
water, make sure that the air has been
released by acting on the manual vents
after having turned the main switch off.
4.2
CONTROL OF THE GAS
PRESSURE UPSTREAM
OF THE BOILER
If.the.upstream.pressure.is.between.11.5.
and. 15. mbar. the. boiler. is. functioning,.
though.at.an.inferior.maximum.nominal.
power..In.case.of.pressure.less.than.11.5.
mbar.the.gas.pressure.switch.acts.
4.3
GAS VALVE
The.boiler.model.SIT.845.SIGMA.(fig..14).
is. produced. with. gas. valve. set. at. two.
pressure. values:. maximum. and. mini-
mum,. that. correspond. according. to. the.
type. of. gas. to. the. values. indicated. in.
Table 2
..
The.setting.of.the.gas.pressure.at.mini-
mum.and.maximum.values.is.carried.out.
by.SIME:.variations.are.discouraged..
Only.in.the.passing.from.one.type.of.gas.
supply. (methane). to. another. (propane).
is. a. change. in. the. working. pressure.
allowed.
Such an operation must be carried out
by authorised personnel, or the guaran-
tee will lose validity. Once the change in
working pressure has been carried out,
seal the regulators.
When.proceeding.with.the.setting.of.the.
pressure,.it.is.necessary.to.follow.a.pre-
established. order,. regulating. first. the.
MAxIMUM.and.then.the.MINIMUM.
4.3.1 Maximum and minimum
pressure adjustment
In. order. to. carry. out. the. setting. of. the.
maximum. proceed. in. the. following. way.
(fig..15):
–. Connect. a. differential. manometer. as.
shown.in.fig..14.
–. Remove.the.plastic.cap.of.the.modu-
lator.(1).
–. Start.the.boiler.by.pressing.on.the.four.
way.switch.
–. Place.the.heating.potentiometer.knob.
on.the.maximum.value.
–. Using.a..ø.10.wrench.turn.the.nut.(3).to.
find.the.maximum.pressure.as.shown.
in.
Table 2
:.to.reduce.the.pressure.turn.
the.nut.anti-clockwise,.to.increase.the.
pressure.turn.the.nut.clockwise.
–. Turn. off. and. turn. on. the. burner. 2-3.
times.to.verify.that.the.pressure.corre-
sponds.to.the.values.given.in.
Table 2
..
After. having. regulated. the. maximum.
pressure,.proceed.with.the.setting.of.the.
minimum.pressure.
–. Disconnect. the. electric. supply. of. the.
modulator.
–. With. the. heating. potentiometer. knob.
on. the. maximum. value. and. the. bur-
ner. alight,. holding. the. nut. (3). blocked,.
turn. the. screw. (2). to. find. the. minimum.
pressure. value. as. shown. in.
Table 2
:. to.
decrease.the.pressure.turn.the.nut.anti-
clockwise. and. to. increase. the. pressure.
turn.the.nut.clockwise.
–. Turn. on. and. turn. off. the. burner. 2-3.
times.to.verify.that.the.pressure.corre-
sponds.to.the.values.given.in.
Table 2
.
–. Reconnect.the.electrical.supply.of.the.
modulator.
–. Replace.the.plastic.cap.(1).
4.4
ADJUSTMENT OF HEATING
OUTPUT
.
To. regulate. the. heat. putput,. modifying.
the. factory. settings,. which. is. the. mini-
mum. thermal. power. for. each. model.
(17.8.-.24.1.kW),.it.is.necessary.to.work.
with.a.screwdriver.on.the.trimmer.of.the.
heating.power.(10.fig..10)...
To.increase.the.operating.pressure.turn.
the. trimmer. in. a. clockwise. direction,. to.
decrease.the.pressure.turn.the.trimmer.
in.an.anti-clockwise.direction..
To.facilitate.the.search.for.the.adjusting.
of.the.heating.power.the.diagrams.pres-
3
2
1
Fig..15
KEY
1. Plastic.cap.
2. Screw.regulation.minimum.pressure
3. Nut.regulation.maximum.pressure
4
USE AND MAINTENANCE
TABLE 2
3
4
2
1
5
Fig..14
KEY
1. Modulator
2. EV1-EV2.coils
3. Upstream.pressure.plug
4. Downstream.pressure.plug.
5. Manometer
.
.
.
22
32 - 32/50 - 32/80
Methane - G20
Maximum.burner.pressure.. mbar.
.
12,7.
12,7
Minimum.burner.pressure..
mbar.
.
7,3.
7,3
Propane - G31
Maximum.burner.pressure.
mbar.
.
28,4.
28,4
Minimum.burner.pressure..
mbar.
.
16,6.
16,6
Содержание LOGO 22 OF TS
Страница 1: ...IT ES PT GB DE RO...
Страница 2: ......
Страница 4: ......
Страница 33: ...29...
Страница 34: ...30...
Страница 35: ......
Страница 64: ...31...
Страница 65: ......
Страница 93: ......
Страница 123: ......
Страница 151: ......
Страница 180: ......
Страница 181: ......
Страница 182: ......
Страница 183: ......