2.7
LOGICA REMOTE CONTROL
All. the. boiler’s. functions. can. be. mana-
ged. by. a. optional. digital. multifunctional.
device. code. 8092204. for. the. remote. of.
the.boiler.itself.and.for.regulating.room.
climatic. conditions. with. an. operational.
reserve.of.12.hours.
The. heating. circuit. is. controlled. by. the.
room. temperature. sensor. built-in. the.
equipment. or. by. the. atmospheric. con-
ditions,. with. or. without. environmental.
inflow,. if. the. boiler. is. connected. to. an.
external.sensor.
Characteristics:
–
Ergonomic.control.unit.divided.accor-
ding.to.function.(control.levels)).
–
Clear.division.of.basic.functions:
•
. operating. regime,. correction. of.
set. value. and. presence. button. are.
directly.accessible;
•
. Different. real. current. values. are.
accessible. through. the. “info”. but-
ton;
•
. other.functions.can.be.programmed.
after.the.cover.has.been.opened;
•
. special.service.level.with.protected.
access;
–
Each.setting.or.modification.is.displa-
yed.and.confirmed.
–
Tome.setting.(special.line.for.changing.
BST/CET).
–
Heating. programme. with. max.. 3.
heating. periods. per. day,. individually.
selectable.
–
Copy. function. for. easy. transfer. of.
heating. programme. to. the. next. or.
previous.day.
–
Holiday. programme:. the. programme.
is. interrupted. for. the. holiday. period.
and. automatically. restarted. on. retur-
ning.home.
–
Option. to. return. the. heating. program.
to.default.values.
–
Programming.lock.(child.safety).
Functions:
–
Delivery. temperature. control. guided.
by. the. atmospheric. conditions,. taking.
into.account.the.dynamics.of.the.buil-
ding.
–
Delivery.temperature.control.guided.by.
atmospheric.conditions.with.influence.
of.ambient.temperature.
–
Ambient.temperature.control.only.
–
Adjustable. influence. of. ambient. tem-
perature.shift..
–
Switch-on. and. switch-off. optimisa-
tion.
–
Rapid.lowering.
–
ECO. functions. (daily. heating. limiter,.
automatic. summer/winter. switch-
over).
–
Controllable. maximum. delivery. tem-
perature. limit. (specifically. for. floor.
plants).
–
Limitation.of.increase.in.pre-set.deli-
very.temperature.
–
Anti-freeze.protection.for.buildings.
–. Hourly. programming. of. the. tank. unit.
temperature. on. two. levels:. comfort.
and.reduced.
–
Domestic.hot.water.control.with.nomi-
nal.value.requirement.and.enable.
–
Connection. to. room. sensor. or.
switching.of.operating.regime.through.
the. telephone. system. with. external.
contact.or.through.a.window.contact.
–. Anti-bacterial.
2.7.1 Installation
The. unit. must. be. installed. in. the. main.
living. room.. For. installation,. follow. the.
assembly. instructions. inserted. in. the.
package..
At.this.point,.with.the.selector.knob.on.
(
),.the.installer.can.adjust.the.basic.
parameters. settings. according. to. the.
individual.needs..
If there is a thermostatic radiator valve
fitted, this must be set to maximum.
2.7.2 Installation settings
The.settings.for.the.basic.operating.para-
meters.for.individual.needs.are.reported.
in. the. instruction. leaflet. supplied. with.
the. “Logica. Remote. Control”. and. in. the.
section. reserved. for. the. user. in. this.
manual.
For. further. adjustments. which. can. be.
carried. out. by. the. installer,. the. “Logica.
Remote.Control”.offers.a.level.of.service.
and. parameterising. which. can. only. be.
accessed.through.a.special.combination.
of.buttons.
To.activate.this.level.of.service.or.para-
meterising. press. buttons
and.
least. 5. seconds.. This. will. activate. the.
parameterising.level..Then.use.the.same.
arrow. buttons. to. select. the. individual.
input. lines. and. adjust. the. values. with
or.
.
98
Antifreeze protection
“Pre-set ambient
temperature value”
Summer/Winter switch-over
temperature
Type of control:
0 = with ambient influence
1 = without ambient influence
Influence of ambient temperature
Heating.takes.place.up.to.this.pre-set.value.if.the.plant.is.activated.in.
standby.(e.g..holidays)..
In. this. way,. the. building. antifreeze. function. is. active,. preventing. an.
excessive.lowering.of.the.ambient.
This.parameter.regulates.the.temperature.of.the.automatic.summer/
winter.switch-over.
This.parameter.de-activates.the.ambient.influence.and.as.a.result.all.
the.optimisations.and.adaptations..
If. a. valid. external. temperature. is. not. transmitted. ,. the. controller.
switches.to.the..pure.ambient.control.guide.variable.
If.the.ambient.controller.is.used.only.as.a.remote.control.(placed.in.the.
reference.room.and.without.an.external.sensor.connected),.the.value.
must.be.set.at.0.(zero)..
If.the.change.in.ambient.temperature.from.the.pre-set.value.remains.
high. during. the. entire. day,. the. influence. must. be. increased.. If. the.
ambient.temperature.is.around.the.pre-set.value.(control.oscillation),.
the.influence.must.be.reduced..
Note: If the ambient temperature influence constant is set at 0, the
adaptation of the heating curve is deactivated. In this case, parameter
57 will have no effect at all.
54
HEATING.CIRCUIT.SETTINGS
52
53
51
Содержание LOGO 22 OF TS
Страница 1: ...IT ES PT GB DE RO...
Страница 2: ......
Страница 4: ......
Страница 33: ...29...
Страница 34: ...30...
Страница 35: ......
Страница 64: ...31...
Страница 65: ......
Страница 93: ......
Страница 123: ......
Страница 151: ......
Страница 180: ......
Страница 181: ......
Страница 182: ......
Страница 183: ......