34
– Refit in reverse order ensure cartridge
is locked in position
6.18
WATER PRESSURE
SWITCH
– Isolate boiler
– Remove cover
– Isolate flow and return valves
– Drain boiler using drain vent
– Remove clip below flow switch
– Disconnect lead from sensor
– Lift switch upwards
– Refit in reverse order
6.19
DHW FLOW SENSOR
– Isolate boiler
– Remove cover
– Remove cable from flow sensor and pull
forward
– Lift flow sensor blue clip pull forward
– Refit in reverse order
6.20 CONDENSE
SENSOR
– Isolate boiler
– Remove cover
– Disconnect the wiring
– Disconnect the sensor
– Refit in reverse order.
6.21 CONDENSE
TRAP
– Isolate boiler
– Remove cover
– Remove sensor as described in 6.20
– Remove the screws securing the trap
to its mounting bracket.
– Refit in reverse order
6.22 PRINTED CIRCUIT
BOARD (PCB)
– Isolate boiler
– Remove cover
– Remove the control panel fixing
screws
– Lower the panel to the horizontal
position
– Remove the PCB cover
– Disconnect the wiring from the PCB
– Release the plastic "latches" securing
the PCB
– Lift out the PCB
– Refit in reverse order
– PAR 1 and PAR2 will need to be set
(as shown in section 4.2.1
6.23
MANUAL BY-PASS
– Isolate boiler
– Remove cover
– Isolate flow and return valves
– Drain boiler using drain vent
– Remove clip
– Pull bypass valve forward
– Refit in reverse order
– Checking seals