– Remove the securing clip at retaining
the plug at the LHS of diverter assembly
NOTE: a internal spring will push off the
plug. Retain
– Remove internal bush from spindle
– Remove diverter valve head securing
clip
– Pull diverter valve head from assembly
– Remove spindle from assembly comple-
te with bush and spacer
– Replace in reverse order replacing “O”
rings as required
6.16
Auto Air Vent (AAV)
– Isolate power supply
– Isolate flow and return valves
– Remove boiler cover
– Drain boiler using drain vent
– Remove AAV
– Replace in reverse order
6.17
Safety Valve
– Isolate power supply
– Isolate flow and return valves
– Remove boiler cover
– Drain boiler using drain vent
– Disconnect pipe from safety valve
– Remove safety valve securing clip
– Remove safety valve, catch any water
lost
– Refit in reverse
6.18
Pressure / Temperature Gauge
– Isolate power supply
– Isolate flow and return valves
– Remove boiler cover
– Drain boiler using drain vent
– Remove the clip securing the pressure
sensor
– Remove the clip securing thermometer
bulb
– Carefully remove the gauge
– Refit in reverse order