66
Internal Condensate Pipe Discharge Termination
Figure 3 –
Connection of a condensate pump - typical method (NB manufacturer’s detailed
instructions should be followed).
Note – Any external pipe work should be insulated, pipe cut at 45 degrees and a drain/ leaf
Key
1
Condensate discharge from boiler
2
Condensate pump
3
Visible air break at plug hole
4
5
75mm sink waste trap
2
5
4
3
Key
1
Boiler
2
Visible air break at plug hole
3
75 mm sink, basin, bath or shower
waste trap
4
Sink, basin, bath or shower with
5
Open end of condensate discharge
pipe direct into gully 25 mm min below
grating but above water level; end cut
at 45 °
Note – the maximum external
condensate discharge length is 3 metres
6
Minimum internal diameter 19 mm
7
Pipe size transition
8
Minimum internal diameter 30 mm
9
Water/weather proof insulation
10
Fit drain cover/leaf guard
1
1
2
3
4
5
10
6
7
8
9
October 2018 Issue 1.0
Содержание 8116910
Страница 4: ...4 ...
Страница 14: ...14 ...
Страница 54: ...54 9 EXPLODED VIEWS Frame ...
Страница 55: ...55 Hydraulic assembly ...
Страница 56: ...56 Exchanger Combustion ...
Страница 57: ...57 Control panel ...
Страница 58: ...58 Gas valve Air gas duct Fan ...
Страница 79: ...79 ...