40
7.4
List of parameters
a
WARNING
To set parameter PAR 01 correctly, check the fan model on the technical data plate and set the parameter according to
the installed model:
–
(*)
= with fan model "ebmpapst nrg118"
–
(**)
= with fan model "sit ng30".
Type
No.
Description
Range
U/M
Step
Default
CONFIGURATION
PAR
01
Index showing boiler power in kW
0 = 25 kW (G20) **
1 = 25 kW (G20) *
5 = 35 kW (G20)
6 = 25 kW (G31) **
7 = 25 kW (G31) *
11 = 35 kW (G31)
-
1
0, 1, 5, 6,
7 or 11
PAR
02
Hydraulic configuration
0 = combi
1 = system
2 = N/A
3 = N/A
4=instant with solar power input
5 = open vent
6 = boiler with heat pump
9 = Hybrid Wall
10 = Hybrid Wall "T" hot water tank boiler
-
1
2
PAR
07
Thermal gradient for Hybrid Wall
defrosting aid
0 .. 30
°C/min
1
10
PAR
08
External sensor value correction
-5 .. +5
°C
1
0
PAR
09
Ignition fan speed
80 .. 160
RPMx25
1
128
DOMESTIC HOT WATER - HEATING
PAR
10
Boiler Antifreeze Threshold
0 .. +10
°C
1
3
PAR
11
External Sensor Antifreeze Threshold
-- = Disabled
-9 .. +5
°C
1
-2
PAR
12
Heating Curve Incline
0 .. 80
-
1
20
PAR
13
Minimum Heating Temperature Adjust-
ment
20 .. PAR 14
°C
1
20
PAR
14
Maximum Heating Temperature Ad-
justment
PAR 13 .. 80
°C
1
80
PAR
15
Maximum power in CH mode
0 .. 100
%
1
100
PAR
16
Heating Post-Circulation Time
0 .. 99
seconds
x 10
1
3
PAR
17
Heating Pump Activation Delay
0 .. 60
seconds
x 10
1
0
PAR
18
Heating Re-ignition Delay
0 .. 60
Min
1
3
PAR
19
Domestic Hot Water Modulation with
Flow meter
0 = Disabled
1 = Enabled
-
1
1
PAR
20
Maximum power domestic hot water
0 .. 100
%
1
100
PAR
21
Minimum power heating/domestic hot
water (premixed)
0 .. 100
%
1
0
PAR
22
Domestic hot water preheating ena-
bling
0 = OFF
1 = ON
-
1
0
PAR
23
External relay 1 function
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
9 = boiler with heat pump (circulator)
-
-
0
PAR
24
External relay 2 function
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
9 = boiler with heat pump (circulator)
13 = management of the heat pump for Hybrid
Wall
-
-
0