31
6.12.3 Installation of separate ducts 80mm
The boiler can be installed with separate air inlet and exhaust ducts. The figure below illustrate some examples of the fluing
options allowed and the associated losses of the accessories. The total load loss is the sum of the load losses of the accessories
used. The maximum load loss
must not exceed 16.5 mm H2O
for
Edea 25 T
and
30.0 mm H2O
for
Edea 35 T
. The maximum flue length
must not exceed 25 m
inlet and exhaust.
9
C
C33
11
10
3
1
1
3
3
7
3
12
12
12
C13
3
2
3
1
14
12
13
12
NOTE
Before connecting accessories, it is
always advisable to lubricate the
internal part of the gaskets with
silicon products. Avoid using oils
and greases.
Load loss - mm H
2
O
Inlet
Exhaust
1 Air/smoke divider, code 8093050
0
0
Inlet
0
0
0.3
0.4
0.25
0.25
0.13
0.13
0.25
0.25
--
--
--
--
1.5
0.2
--
--
1.5
0.2
2 90° bend, code 8077450
0.25
3 a Extension 80mm L. 1000, code 8077351
3 b Extension 80mm L. 500, code 8077350
7 45° bend, code 8077451
0.20
9 Inlet/ exhaust fitting, code 8091401
--
--
10 Articulated tile, code 8091300
--
--
11 Vertical roof terminal, code 8091204 *
13 Inlet/ exhaust fitting, code 8091401
--
--
14 Coaxial Terminal, code 8091204 *
1.10
* This loss includes the losses with use of item 9 or 13
EDEA 25 T
Load loss - mm H
2
O
EDEA 35 T
0.20
0.10
0.30
0.20
0.10
0.20
0.15
0.15
--
2.8
--
1.8
1.10
Exhaust
15 Duct kit C(10)3, code 6296543
Fig. 26
6.12.4 Coaxial duct (Ø 60/100mm and Ø 80/125mm)
Coaxial accessories
Description
Code
Ø 60/100 mm
Ø 80/125 mm
Coaxial duct kit
8096250
8096253
Extension W. 1000 mm
8096150
8096171
Extension W. 500 mm
8096151
8096170
Vertical extension W. 140 mm
with smoke analysis take-off
point
8086950
-
Adapter for Ø 80/125 mm
-
8093150
Additional 90° curve
8095850
8095870
Additional 45° curve
8095950
8095970
Tile with joint
8091300
8091300
Roof outlet terminal W. 1284
mm
8091205
8091205
Load loss - Equivalent lengths
Model
Leq (linear metres)
Ø 60/100 mm
Ø 80/125 mm
90° curve
1,5
2
45° curve
1
1
With a Ø 60/100 mm coaxial outlet duct exceeding 2 metres,
remove, by turning it clockwise, the smoke outlet diaphragm
(1) positioned as shown in the picture. With a Ø 80/125 mm
coaxial outlet duct exceeding 4 metres, remove, by turning
it clockwise, the smoke outlet diaphragm (1) positioned as
shown in the picture.
a
b
1
Fig. 27
Minimum-Maximum Lengths
Model
Duct Length Ø 60/100
Duct Length Ø 80/125
W Horizontal (m) H Vertical
(m)
W Horizon-
tal (m)
H Vertical
(m)
Min.
Max. Min. Max. Min. Max. Min. Max.
Edea 25 T
-
6
1,3
8
-
12
1,2
15
Edea 35 T
-
6
1,3
8
-
12
1,2
15