“DEWY EQUIPE P100 BOX”
SINGLE MODULE MALFUNCTIONS
–
Ignition lock
(fig. 3)
If the burner does not light the red led ( )
turns on. To attempt ignition again, rotate
the selector knob to ( ) and release it
immediately after returning it to winter
operations (
).
If it locks again, request an authorised
service control.
–
Insufficient water pressure
(fig. 4)
If the
“0.5 bar”
red light blinks, the
module does not work. To restore opera-
tions, fill the system until the green
“1
bar”
led turns on. If all leds are of f,
request an authorised service call.
–
Safety/exhaust thermostat
triggered
(fig. 5)
If the safety/exhaust thermostat trig-
gers the red
“35°C”
led blinks.
To attempt ignition again, rotate the
selector knob to ( ) and release it imme-
diately after returning it to winter opera-
tions (
).
If it locks again, request an authorised
service control.
–
Other faults
(fig. 6)
When one of the red
“40÷80°C”
leds
blinks, turn off the generator and attempt
ignition again.
This operation can be repeated 2-3 times
at most, in the event of failure, request an
authorised service call
Fig. 6
SPIA ROSSA
Fig. 3
Fig. 4
SPIA ROSSA INTERMITTENTE
IN CONDIZIONE DI SICUREZZA
SPIA VERDE IN CONDIZIONE
DI FUNZIONAMENTO
SPIA ROSSA INTERMITTENTE
Fig. 5
SPIA ROSSA INTERMITTENTE
RED LIGHT
BLINKING RED LIGHT
BLINKING RED LIGHT
BLINKING RED LIGHT
IN SAFETY CONDITIONS
GREEN LIGHT
IN OPERATING CONDITIONS