87
EN
8.2.8
Replacing the coil
To replace the coil:
– remove the connector (1)
– remove the nut (2) using the spanner provided
– extract the coil (3) and replace it
2
1
3
Fig. 67
– mount the components back on by performing the above
steps in reverse order.
8.2.9
Replacing the capacitor
To replace the capacitor:
– remove the protective cap (1) from the capacitor (2)
– disconnect the power supply to the capacitor
– connect a tester to the Faston terminals of the capacitor; if the
reading is roughly 10% higher than the rated capacity shown
on the capacitor, it means that the capacitor is damaged.
1
2
Fig. 68
– remove the capacitor (2) and replace it
– mount the components back on by performing the above
steps in reverse order.
8.2.10 Cleaning the impeller
To clean the fan impeller:
– loosen the screws (1) and remove the air intake duct (2)
– clean the impeller (3) and the inside of the fan using a paint-
brush
– if necessary, dismantle the impeller and mount it back on.
2
3
1
Fig. 69
If the motor and/or impeller (3) must be replaced, make sure
that the lower rotation surface (A) of the impeller is roughly 1
mm away from the surface (B) of the housing body, as illustrated
in the figure.
OK
NO
NO
~ 1mm
A
3
B
Fig. 70
Содержание 8103296
Страница 2: ...2...
Страница 6: ...6 IT...
Страница 12: ...12 IT...
Страница 26: ...26 IT...
Страница 47: ...47 IT...
Страница 48: ...48 EN...
Страница 52: ...52 EN...
Страница 58: ...58 EN...
Страница 72: ...72 EN...
Страница 93: ...93 EN...
Страница 97: ...97 EN IT...
Страница 98: ...98 EN IT...
Страница 99: ...99...
Страница 100: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 www sime it...