SIM5350 AT Command Set
6.26
AT+ECELCK Cell Lock
Description
This command is used to set or cancel cell lock, and get the currently locked cell if any.
SIM PIN References
YES
Vender
Syntax
Test Command
Responses
AT+ECELCK=?
+ ECELCK: (0-1)
Read Command
Responses
AT+ECELCK?
+ECELCK:
<enabled_bitmap>,<band_indicator>,<arfcn>,[<arfcn>,…]
OK
Write Command
Responses
OK
AT+ECELCK=
<mode>,[<en
abled_bitmap>,]<band_indic
ator>,<arfcn>,[<arfcn>,…]
ERROR
Defined values
<mode>
integer type
0: cancel cell lock (for the only <arfcn>)
1: set cell lock (for the only <arfcn>)
2: get extended cell lock, this will get the current locked cells’ arfcn.
3: set extended cell lock, this will set lock for a group of cells by different arfcn (maximum 3).
Only in this mode, more than one <arfcn> can be entered in the following parameter.
4: cancel extended cell lock, this will cancel all cell lock.
<enabled_bitmap>
integer type 0~7
Bits set to 1 indicate which <arfcn> to be locked.
Ex. 00000101 => the 1st and 3rd <arfcn> is valid.
<band_indicator>
integer type
0: not 1900 band cell
1: 1900 band cell
<arfcn>
SIM5350_ATC_V1.02