![SimCom SIM5350 Скачать руководство пользователя страница 138](http://html1.mh-extra.com/html/simcom/sim5350/sim5350_command-set_1274792138.webp)
SIM5350 AT Command Set
This command is used to read values from register of IIC device.
SIM PIN References
NO
Vendor
Syntax
Test Command
Responses
AT+CRIIC=?
OK
Write Command
Responses
+CRIIC:
<data>
OK
AT+CRIIC=
<addr>,<reg>
ERROR
Defined values
<addr>
Device address. Input format must be hex, such as 0xFF.
<reg>
Register address. Input format must be hex, such as 0xFF.
<data>
Data read. Input format must be hex, such as 0x00—0xFF.
Examples
AT+CRIIC=0x1A, 0x0F
+CRIIC: 0x12
OK
9.11
AT+CFGRI Indicate RI when using URC
Description
This command is used to config whether pulling down the RI pin of UART when URC reported. If
<status>
is 1, host may be wake up by RI pin.
SIM PIN References
NO
Vendor
Syntax
Test Command
Responses
AT+CFGRI=?
+CFGRI: (range of supported
<status>
s), (range of supported
<save>
s)
SIM5350_ATC_V1.02
6/9/2014
137