![SimCom SIM5350 Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/simcom/sim5350/sim5350_command-set_1274792131.webp)
SIM5350 AT Command Set
This command is used to configure the output frequency and duty for the PWM pin, the
default frequency and duty is zero.
SIM PIN References
NO
Vendor
Syntax
Test Command
Responses
AT+CPWM=?
OK
Read Command
Responses
+CPWM:
<freq>,<duty>
OK
AT+CPWM?
ERROR
Write Command
Responses
OK
AT+CPWM=
<freq>,<duty>
ERROR
Defined values
<
freq
>
output frequency of the PWM pin, 200Hz is recommended and also confirmed
<
duty
>
0 - 100 duty cycle
Examples
AT+CPWM?
+CPWM: 200,20
OK
AT+CPWM=200,40
OK
9.3
AT+CPWMCLKS Select the source clock for the PWM
Description
This command is used to select a clock as the source clock for the PWM pin, the default
value is 3
SIM PIN References
NO
Vendor
SIM5350_ATC_V1.02
6/9/2014
130
Содержание SIM5350
Страница 1: ...AT Command Set SIM5350 _ATC_V1 02...