background image

3

Ioncell

5201128 Rev. D

The ionizer can be powered by a universal input, low voltage power supply, or 

through a 24 VDC power bus in the host main circuit. Multiple Ioncells can be 

linked together from a single power supply, allowing up to 6 units to be daisy-

chained. 
Operation of the Ioncell is automatically regulated by built-in proprietary circuitry. 

A green light on the face of the ionizer indicates active condition. A red light 

will indicate if a fault condition has occurred. Mounting holes for the ionizer are 

provided within the integral base of the unit. 
The in-line Ioncell is equipped for use with pressurized CDA only (clean dry air). 

Ioncell emitter points are general purpose Tungsten.

3. SPECIFICATIONS 

Input Voltage

Power Supply: Universal, 100-240 VAC, 50/60 Hz (24 VDC, 1.6A output)
Ioncell: 24 VDC, 0.1A (0.17A with optional fan)

Output Voltage

±4500 VDC, 5µA, Steady State

Offset Voltage

±50V

Enclosure 

White Polycarbonate (UL 94V-0 flammability rating) 

Alarm Output

TTL level alarm output

Indicators

Green, POWER ON;  Red, FAULT

Mounting

Integral mounting flanges accept four (4) #4 or #6 [M3 or M4] screws (not supplied)

Emitter Pins

Four (4), Tungsten

Operating Temp 

32-122°F [0-50°C]; non-condensing

Dimensions

Standard:  1.25”H x 1.3”W x 4.5”L [32 x 33 x 115 mm]

In-Line:  2.5”H x 1.3”W x 4.5”L  [64 x 33 x 115 mm]

Weight 

5.2 oz [145g]

Gas Input

In-Line: 45 psi [3.1 bar] max; clean dry air only

Gas Flow

In-Line: 0.8 scfm @ 5 psi to 3.2 scfm @ 45 psi [23 l/m @ 0.34 bar to 92 l/m @ 3.1 bar]

Airflow

5 cfm [0.14 m3/min] with optional fan

Discharge Time

Standard Ioncell: <15 seconds @ 6” [150 mm] to CPM plate 1000-100V
Ioncell with optional fan: <10 seconds @ 12” [300 mm] to CPM plate
In-Line Ioncell with output tube: 1” [25 mm] to CPM plate, 1000-100V

Tube Length

30 psi [2.0 bar]

15 psi [1.0 bar]

5 psi [0.34 bar]

6” [150 mm]

0.5 sec

0.8 sec

1.4 sec

12” [300 mm]

0.8 sec

1.4 sec

2.2 sec

18” [460 mm]

1.0 sec

2.1 sec

3.5 sec

24” [610 mm

1.8 sec

3.2 sec

5.2 sec

36” [910 mm]

6.0 sec

6.8 sec

10 sec

48” [1220 mm]

9.5 sec

13 sec

22 sec

Содержание Ioncell

Страница 1: ...5201128 Rev D Ioncell Ioncell Standard and In Line Ionizer INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...i Ioncell 5201128 Rev D TABLE OF CONTENTS 1 SAFETY WARNINGS 1 2 DESCRIPTION 2 3 SPECIFICATIONS 3 4 INSTALLATION 4 5 MAINTENANCE 8 6 PARTS AND ACCESSORIES 9 9 WARRANTY AND SERVICE 10 ...

Страница 3: ...rds ATTENTION Les déclarations identifiées avec ATTENTION indiquent des dangers potentiels pour la sécurité WARNING Statements identified with WARNING indicate potential serious injury hazards AVERTISSEMENT Les déclarations identifiées avec AVERTISSEMENT indiquent un risque de blessures graves NOTE This equipment must be correctly installed and properly maintained Adhere to the following notes for...

Страница 4: ...sure Gardez les mains doigts éloignés 1 Read Instruction Manual completely before proceeding with installation or operation Failure to follow instructions may result in damage to Ioncell ionizer or power supply 2 The Ioncell ionizer when operated with optional power supply is to be connected to main electric source with included 3 wire line cord and grounded plug set Do not remove electrical groun...

Страница 5: ... OffsetVoltage 50V Enclosure White Polycarbonate UL 94V 0 flammability rating Alarm Output TTL level alarm output Indicators Green POWER ON Red FAULT Mounting Integral mounting flanges accept four 4 4 or 6 M3 or M4 screws not supplied Emitter Pins Four 4 Tungsten OperatingTemp 32 122 F 0 50 C non condensing Dimensions Standard 1 25 H x 1 3 W x 4 5 L 32 x 33 x 115 mm In Line 2 5 H x 1 3 W x 4 5 L 6...

Страница 6: ...g static neutralization for best ionizer performance CAUTION This product is intended to be supplied by a Listed AC Adapter or Power Unit marked Class 2 or LPS and rated output 24 VDC 1 7A ATTENTION Ce produit est destiné à être alimenté par un adaptateur de courant alternatif ou transformateur listé classe 2 ou LPS et avec une puissance nominale 24 VDC 1 7A Optional fan assembly mounting and conn...

Страница 7: ...be lengths will increase discharge times NOTE Tubing must have the same inside diameter on both sides of the in line manifold A 5 VDC TTL level alarm output is provided for remote monitoring of the ionizer operating condition ALARM goes high 5 VDC on alarm See Figure 2 for complete connection diagram Optional Airflow Switch for In line Ioncells The airflow switch replaces the power cable between t...

Страница 8: ...odular connector RJ 11 extension cable 72 1830mm long included with power supply RJ11 extension cable 36 915 mm long included with Ioncell ionizer Line Cord 72 1830 mm long included with power supply Red Black Direct Power Bus Cable 72 1830 mm long units with no power supply Customer supplied 24 VDC Figure 2 Up to 6 six Ioncells can be attached to one power supply ...

Страница 9: ...7 Ioncell 5201128 Rev D Figure 3 Dimensional Drawing ...

Страница 10: ...d cleanliness of the location where the ionizer is operated Occasional cleaning of the ionizer housing may be accomplished with a clean cloth moistened with common glass cleaning solution The recommended emitter cleaning procedure is as follows 1 Turn the ionizer off by disconnecting it from the electrical power source 2 Simco Ion recommends using the ITW TEXWIPE model TX726 Crush Tube product for...

Страница 11: ...for Standard Ioncell 5051983 6 Air Knife Applicator for In line Ioncell 5051678 12 Air Knife Applicator for In line Ioncell 5051679 6 Air Ring Applicator for In line Ioncell 5051680 10 Air Ring Applicator for In line Ioncell 5051681 Airflow Switch for In line Ioncell 5051685 Item Replacement Parts Part Number 1 Universal Power Supply with 72 1830 mm Line Cord 5051677 2 Direct Power Cable 72 1830 m...

Страница 12: ...d with misused improperly installed altered has received damage through abuse carelessness accident connection to improper line voltage or has been serviced by anyone other than an authorized factory representative The warranty does not apply when Simco Ion parts and equipment have been energized by other than the appropriate Simco Ion power supply or generator or when a Simco Ion power supply or ...

Отзывы: