6. PARTS AND ACCESSORIES

Parts

Part Number

Standard Ioncell Ionizer Kit with Power Supply, includes items 1, 3 below

4017139

Standard Ioncell Ionizer Kit (no Power Supply), includes items 2, 3 below

4017140

In-line Ioncell Ionizer Kit with Power Supply, includes items 1, 3, 5 below

4015281

In-line Ioncell Ionizer Kit (no Power Supply), includes items 2, 3, 5 below

4015477

Accessories

Part Number

Fan Assembly Kit (for Standard Ioncell)

5051983

6” Air Knife Applicator (for In-line Ioncell)

5051678

12” Air Knife Applicator (for In-line Ioncell)

5051679

6” Air Ring Applicator (for In-line Ioncell)

5051680

10” Air Ring Applicator (for In-line Ioncell)

5051681

Airflow Switch (for In-line Ioncell)

5051685

Item

Replacement Parts

Part Number

1

Universal Power Supply with 72” [1830 mm] Line Cord

5051677

2

Direct Power Cable, 72” [1830 mm] for user supplied 24VDC

5051688

3

Ioncell Interconnect Cable, 36” [915 mm]

4520764

4

Ioncell Interconnect Cable, 72” [1830 mm]

4520767

5

Tubing and Splitter Kit, for In-line Ioncell

5051683

6

Tungsten Electrode Replacement Kit

5051288

Содержание Ioncell

Страница 1: ...5201128 Rev D Ioncell Ioncell Standard and In Line Ionizer INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...i Ioncell 5201128 Rev D TABLE OF CONTENTS 1 SAFETY WARNINGS 1 2 DESCRIPTION 2 3 SPECIFICATIONS 3 4 INSTALLATION 4 5 MAINTENANCE 8 6 PARTS AND ACCESSORIES 9 9 WARRANTY AND SERVICE 10 ...

Страница 3: ...rds ATTENTION Les déclarations identifiées avec ATTENTION indiquent des dangers potentiels pour la sécurité WARNING Statements identified with WARNING indicate potential serious injury hazards AVERTISSEMENT Les déclarations identifiées avec AVERTISSEMENT indiquent un risque de blessures graves NOTE This equipment must be correctly installed and properly maintained Adhere to the following notes for...

Страница 4: ...sure Gardez les mains doigts éloignés 1 Read Instruction Manual completely before proceeding with installation or operation Failure to follow instructions may result in damage to Ioncell ionizer or power supply 2 The Ioncell ionizer when operated with optional power supply is to be connected to main electric source with included 3 wire line cord and grounded plug set Do not remove electrical groun...

Страница 5: ... OffsetVoltage 50V Enclosure White Polycarbonate UL 94V 0 flammability rating Alarm Output TTL level alarm output Indicators Green POWER ON Red FAULT Mounting Integral mounting flanges accept four 4 4 or 6 M3 or M4 screws not supplied Emitter Pins Four 4 Tungsten OperatingTemp 32 122 F 0 50 C non condensing Dimensions Standard 1 25 H x 1 3 W x 4 5 L 32 x 33 x 115 mm In Line 2 5 H x 1 3 W x 4 5 L 6...

Страница 6: ...g static neutralization for best ionizer performance CAUTION This product is intended to be supplied by a Listed AC Adapter or Power Unit marked Class 2 or LPS and rated output 24 VDC 1 7A ATTENTION Ce produit est destiné à être alimenté par un adaptateur de courant alternatif ou transformateur listé classe 2 ou LPS et avec une puissance nominale 24 VDC 1 7A Optional fan assembly mounting and conn...

Страница 7: ...be lengths will increase discharge times NOTE Tubing must have the same inside diameter on both sides of the in line manifold A 5 VDC TTL level alarm output is provided for remote monitoring of the ionizer operating condition ALARM goes high 5 VDC on alarm See Figure 2 for complete connection diagram Optional Airflow Switch for In line Ioncells The airflow switch replaces the power cable between t...

Страница 8: ...odular connector RJ 11 extension cable 72 1830mm long included with power supply RJ11 extension cable 36 915 mm long included with Ioncell ionizer Line Cord 72 1830 mm long included with power supply Red Black Direct Power Bus Cable 72 1830 mm long units with no power supply Customer supplied 24 VDC Figure 2 Up to 6 six Ioncells can be attached to one power supply ...

Страница 9: ...7 Ioncell 5201128 Rev D Figure 3 Dimensional Drawing ...

Страница 10: ...d cleanliness of the location where the ionizer is operated Occasional cleaning of the ionizer housing may be accomplished with a clean cloth moistened with common glass cleaning solution The recommended emitter cleaning procedure is as follows 1 Turn the ionizer off by disconnecting it from the electrical power source 2 Simco Ion recommends using the ITW TEXWIPE model TX726 Crush Tube product for...

Страница 11: ...for Standard Ioncell 5051983 6 Air Knife Applicator for In line Ioncell 5051678 12 Air Knife Applicator for In line Ioncell 5051679 6 Air Ring Applicator for In line Ioncell 5051680 10 Air Ring Applicator for In line Ioncell 5051681 Airflow Switch for In line Ioncell 5051685 Item Replacement Parts Part Number 1 Universal Power Supply with 72 1830 mm Line Cord 5051677 2 Direct Power Cable 72 1830 m...

Страница 12: ...d with misused improperly installed altered has received damage through abuse carelessness accident connection to improper line voltage or has been serviced by anyone other than an authorized factory representative The warranty does not apply when Simco Ion parts and equipment have been energized by other than the appropriate Simco Ion power supply or generator or when a Simco Ion power supply or ...

Отзывы:

Похожие инструкции для Ioncell