4. INSTALLATION 

CAUTION – Sharp Points

Risk of injury. Keep hands/fingers away.

ATTENTION – Points pointus

Risqué de blessure. Gardez les mains / doigts éloignés.

NOTE

 – Inspect shipping container and contents for visible damage.  

Report any damage directly to the carrier before attempting installation of 

unit. 

The Ioncell ionizer is designed for fixed position mounting onto a secure equipment 

frame or partition surface. The flanged base of the ionizer may be used as a template, 

or see Figure 2 for complete dimensional information. 
Prepare mounting surface with necessary mounting holes.  Secure with #4 or #6 [M3 

or M4] screw hardware as required.  Mounting hardware is not supplied with unit. 
Important mounting location requirement:  The center of ionizer’s emitter pin grid 

must have a minimum 3” spherical radius clearance to any adjacent equipment 

frame or wall surface.  A clear line of sight is recommended to the area requiring 

static neutralization for best ionizer performance. 

CAUTION

 – This product is intended to be supplied by a Listed AC 

Adapter or Power Unit marked “Class 2” or “LPS” and rated output 24 

VDC, 1.7A.

ATTENTION

 – Ce produit est destiné à être alimenté par un adaptateur 

de courant alternatif ou transformateur listé “ classe 2 “ ou “ LPS “ et avec 

une puissance nominale 24 VDC, 1.7A.

Optional fan assembly mounting and connections: Engage open end of fan assembly 

directly around emitter pin grid area of the ionizer, until it snaps into place.  Secure 

fan assembly by placing fan locking bracket over base of fan assembly and tightening 

set screws (do not over tighten).  Insert power lead connector of fan assembly into 

socket located in the top of ionizer enclosure.  The black wire, pin 1 in the connector 

must be positioned towards the outside of ionizer enclosure.  See Figure 2 for 

complete connection diagram.
After the ionizer mounting has been completed, connect power cable between 

ionizer and power supply. Secure power supply as necessary. Connect line cord from 

power supply to the main electric source. The green light on ionizer will indicate 

normal operation.

Содержание Ioncell

Страница 1: ...5201128 Rev D Ioncell Ioncell Standard and In Line Ionizer INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...i Ioncell 5201128 Rev D TABLE OF CONTENTS 1 SAFETY WARNINGS 1 2 DESCRIPTION 2 3 SPECIFICATIONS 3 4 INSTALLATION 4 5 MAINTENANCE 8 6 PARTS AND ACCESSORIES 9 9 WARRANTY AND SERVICE 10 ...

Страница 3: ...rds ATTENTION Les déclarations identifiées avec ATTENTION indiquent des dangers potentiels pour la sécurité WARNING Statements identified with WARNING indicate potential serious injury hazards AVERTISSEMENT Les déclarations identifiées avec AVERTISSEMENT indiquent un risque de blessures graves NOTE This equipment must be correctly installed and properly maintained Adhere to the following notes for...

Страница 4: ...sure Gardez les mains doigts éloignés 1 Read Instruction Manual completely before proceeding with installation or operation Failure to follow instructions may result in damage to Ioncell ionizer or power supply 2 The Ioncell ionizer when operated with optional power supply is to be connected to main electric source with included 3 wire line cord and grounded plug set Do not remove electrical groun...

Страница 5: ... OffsetVoltage 50V Enclosure White Polycarbonate UL 94V 0 flammability rating Alarm Output TTL level alarm output Indicators Green POWER ON Red FAULT Mounting Integral mounting flanges accept four 4 4 or 6 M3 or M4 screws not supplied Emitter Pins Four 4 Tungsten OperatingTemp 32 122 F 0 50 C non condensing Dimensions Standard 1 25 H x 1 3 W x 4 5 L 32 x 33 x 115 mm In Line 2 5 H x 1 3 W x 4 5 L 6...

Страница 6: ...g static neutralization for best ionizer performance CAUTION This product is intended to be supplied by a Listed AC Adapter or Power Unit marked Class 2 or LPS and rated output 24 VDC 1 7A ATTENTION Ce produit est destiné à être alimenté par un adaptateur de courant alternatif ou transformateur listé classe 2 ou LPS et avec une puissance nominale 24 VDC 1 7A Optional fan assembly mounting and conn...

Страница 7: ...be lengths will increase discharge times NOTE Tubing must have the same inside diameter on both sides of the in line manifold A 5 VDC TTL level alarm output is provided for remote monitoring of the ionizer operating condition ALARM goes high 5 VDC on alarm See Figure 2 for complete connection diagram Optional Airflow Switch for In line Ioncells The airflow switch replaces the power cable between t...

Страница 8: ...odular connector RJ 11 extension cable 72 1830mm long included with power supply RJ11 extension cable 36 915 mm long included with Ioncell ionizer Line Cord 72 1830 mm long included with power supply Red Black Direct Power Bus Cable 72 1830 mm long units with no power supply Customer supplied 24 VDC Figure 2 Up to 6 six Ioncells can be attached to one power supply ...

Страница 9: ...7 Ioncell 5201128 Rev D Figure 3 Dimensional Drawing ...

Страница 10: ...d cleanliness of the location where the ionizer is operated Occasional cleaning of the ionizer housing may be accomplished with a clean cloth moistened with common glass cleaning solution The recommended emitter cleaning procedure is as follows 1 Turn the ionizer off by disconnecting it from the electrical power source 2 Simco Ion recommends using the ITW TEXWIPE model TX726 Crush Tube product for...

Страница 11: ...for Standard Ioncell 5051983 6 Air Knife Applicator for In line Ioncell 5051678 12 Air Knife Applicator for In line Ioncell 5051679 6 Air Ring Applicator for In line Ioncell 5051680 10 Air Ring Applicator for In line Ioncell 5051681 Airflow Switch for In line Ioncell 5051685 Item Replacement Parts Part Number 1 Universal Power Supply with 72 1830 mm Line Cord 5051677 2 Direct Power Cable 72 1830 m...

Страница 12: ...d with misused improperly installed altered has received damage through abuse carelessness accident connection to improper line voltage or has been serviced by anyone other than an authorized factory representative The warranty does not apply when Simco Ion parts and equipment have been energized by other than the appropriate Simco Ion power supply or generator or when a Simco Ion power supply or ...

Отзывы: