19-5225S-M-01 Rev 2
25
3.3 Ionization Mode (OpMode)
About Ionization Modes
The AeroBar allows two different methods of ionization. Both are
appropriate for different situations.
Pulsed DC
mode is recommended for process tool environments
where the distance from the fan filter unit to the target exceeds 24
inches or where fast discharge is necessary. Pulsed DC provides
fast decay times and is a good choice unless large metal objects
(such as a pre-aligner or measurement tool) are within 12 inches
(30 cm) of the AeroBar.
Steady-state DC
mode is recommended when the distance between
the wafer and AeroBar is 8-2 inches (20-30 cm), or when large
metal objects are within 12 inches (30 cm) of the AeroBar.
Steady-state mode may be necessary for most semiconductor tool
applications with tight performance specifications, or when low
swing voltages are required for sensitive devices (i.e., <100V
swings).
About Standby Mode
Standby mode is a convenient way to turn off high voltage to the
ionizer without removing wires or accessing the Interface Module.
Standby mode is useful for maintenance periods where settings
must be remembered.
1. Hold down any button while turning on the remote control. A
password prompt will appear.
Use Pulsed DC Mode
Use Steady-state DC Mode
Distances greater than 24 inches (61 cm)
between AeroBar and wafer
Distances 8-2 inches (20-30 cm) between AeroBar
and wafer, and for sensitive devices (less than
100V swings)
No large metal objects are within 12
inches (30 cm) of AeroBar
Large metal objects are within 12 inches (30 cm) of
the AeroBar
Содержание AeroBar 5225S
Страница 1: ...I O N I Z A T I O N S O L U T I O N S Digital AeroBar Ionization System Model 5225S User s Manual...
Страница 5: ...19 5225S M 01 Rev 2 1 1 Description 1 1 Overview 1 2 Remote Control 1 3 Power Requirements...
Страница 12: ...19 5225S M 01 Rev 2 8...
Страница 13: ...19 5225S M 01 Rev 2 9 2 Installation 2 1 Mounting 2 2 Wiring 2 3 FMS Connection 2 4 Daisy chaining...
Страница 42: ...19 5225S M 01 Rev 2 38...
Страница 51: ...19 5225S M 01 Rev 2 47...
Страница 52: ...19 5225S M 01 Rev 2 48 5 Specifications 5 1 AeroBar Model 5225S 5 2 Parts Accessories 5 3 Dimensional Drawings...
Страница 57: ...19 5225S M 01 Rev 2 53 5 3 Dimensional Drawings Standard Lengths...
Страница 58: ...19 5225S M 01 Rev 2 54 300 mm EFEM Application Lengths...
Страница 59: ...19 5225S M 01 Rev 2 55...
Страница 61: ...19 5225S M 01 Rev 2 57...
Страница 62: ...19 5225S M 01 Rev 2 58 Notes...