Never point the spray gun at persons or animals - risk of injury.

► 

Follow the processing and safety notes of the spraying material and cleaning 

agent manufacturers. In particular, aggressive and caustic materials can cause 

damage to health.

► 

Particle-carrying discharged air must be kept away from the working area and 

operating personnel. However, respiratory protection and work clothing should 

always be worn in accordance with regulations when processing materials with 

the spray gun. Airborne particles can damage your health.

► 

Wear eye protection during painting and cleaning.

► 

Wear hearing protection in the working area of the spray gun. The noise level 

generated by the spray gun is approx. 83 dB (A).

►   

Always make sure that all nuts and bolts have been tightened when starting the 

unit, especially after assembly and maintenance work.

► 

Use only original spare parts, since only then SIMALFA can guarantee the safe 

and fault-free functioning of these parts.

► 

Always depressurize the spray gun after work is completed.

► 

The maximum pressure values from the technical data must be observed.

Please contact ALFA Klebstoffe AG, for further information regarding the safe use of 

the spray gun and the materials used in them.

Connecting supply lines

 

and

 

Operation

Note

Please refer to the explosion drawing (page 2) in these operating instructions to 

perform the work steps listed.

4.1 

Spray Pattern Test

A spray pattern test should always be generated when:
• 

the spray gun is used for the first time

• 

the spray material has been replaced

• 

the gun has been disassembled for maintenance or repair

The spray pattern can be applied to a sample work piece, sheet metal, cardboard or 

paper.

1.  Start operation of the spray gun to generate a spray pattern test (see 

Connecting supply lines and 

Operation

.

2.  Check the spraying pattern trial and change the settings on the spray gun, as 

necessary (see 

4.2 Changing the spray pattern

).

4.2 

Changing the spray pattern

You can change the spray pattern on the G9 2K by making the following settings:

Converting / repairing the spray gun

The air cap / material nozzle / needle combination matching the spraying material 

represents an interactively tuned unit - the nozzle set. Always replace the entire 

nozzle insert to maintain the desired spray pattern quality.

Note

All movable and sliding parts must be greased with gun grease before installation 

in the gun body 

Material connection 

 

Component A

Material connection 

Component B

Air connection

The gun is now ready to be operated.

4.  To allow the air in the material 

hose to escape, operate the trigger 

until a uniform material jet (compo-

nent A) and activator (component 

B) exit from the nozzle.

3.  Set the desired material pressure 

and air pressure on your supply 

unit.

2.  Connect the material supply hoses 

to the material connections (com-

ponent A/ component B) of the 

spray gun.

                                                                                                                                  

1.  Connect the compressed air hose 

to the air connection of the spray 

gun.

Adjusting the material flow volume

The material volume can be regulated by turning the adjusting 

screw (item 9) in or out. The material volume is increased by 

turning it to the left (unscrewing) and reduced by turning it to the 

right (screwing down).

Regulating the material pressure

You can adjust the material pressure only on the pump or the 

pressure tank. Please follow the directions and safety instructions 

of the manufacturer. 

Содержание G9 2K

Страница 1: ...el d utilisation Manual de servicio Instrukcja u ytkowania Zweikomponenten Spritzpistole Two component spray Gun Pistolet pulv risateur deux composants Pistola de pulverizaci n de dos componentes Pist...

Страница 2: ...3 2 SIMALFA G9 2K 1 3 7 6 5 6 4 6 3 6 2 6 1 5 15 4 3 2 14 16 9 8 12 11 10 17 13 18...

Страница 3: ...5 Seite 6 19 Page 20 33 Page 34 47 P gina 48 61 Strona 62 75...

Страница 4: ...nden Sicherheits und Gesundheitsanforderungen entspricht Bei einer nicht mit uns abgestimmten nderung an dem Ger t oder bei einer unsachgem en Verwendung verliert diese Erkl rung ihre G ltigkeit Herst...

Страница 5: ...Abzug kompl 1 V 11 815 67 000 1 V 11 815 67 000 14 Schaftschraube 1 V 11 815 63 000 1 V 11 815 63 000 15 Hebelschraube 1 V 10 301 09 000 1 V 10 301 09 000 16 Steckverschraubung 1 V 66 100 01 148 1 V 6...

Страница 6: ...erialien auf Personen und Tiere das Verspritzen von fl ssigem Stickstoff das Verspritzen von brennbaren Materialien 2 Technische Beschreibung Bei der G9 2K handelt es sich um ein Spritzpistolenmodell...

Страница 7: ...standsetzung zerlegt wurde Die Spritzbildprobe kann auf ein Probewerkst ck Pappe oder Papier abgegeben werden 1 Setzen Sie die Spritzpistole in Betrieb um eine Spritzbildprobe zu erzeugen siehe 4 Vers...

Страница 8: ...el austauschen A Komponente Hinweis Das Einstellma der Materialnadel betr gt 117 mm von der Nadelspitze bis zur Nadelmutter gerechnet 1 3 2 5 3 Ventil B Komponente austauschen 5 4 Undichte Nadelpackun...

Страница 9: ...igt werden und das Spritzergebnis verschlechtern Verwenden Sie zur Reinigung der Spritzpistole nur Reinigungsmittel die vom Hersteller des Spritzmaterials angegeben werden und die folgenden Bestandtei...

Страница 10: ...lose oder besch digt Material auff llen s Betriebsanleitung des Anlagenherstellers festziehen oder austauschen Pistole bl st in Ruhestellung Ventilfeder Pos 6 3 oder Ventilschaft Pos 6 2 besch digt a...

Страница 11: ...ription below corresponds to the relevant based safety and health requirements In the event of changes to the device not agreed on with us or if used improperly this declaration becomes invalid Manufa...

Страница 12: ...11 815 63 000 15 Lever screw 1 V 10 301 09 000 1 V 10 301 09 000 16 Push in fitting 1 V 66 100 01 148 1 V 66 100 01 148 17 Threaded joint 1 V 66 100 06 257 1 V 66 100 06 257 18 Hose 9 cm 1 V 11 815 0...

Страница 13: ...ludes for example spraying materials on persons and animals spraying liquid nitrogen spraying of flammable materials 2 Technical description The G9 2K is a spray gun model for the application of two c...

Страница 14: ...nce or repair The spray pattern can be applied to a sample work piece sheet metal cardboard or paper 1 Start operation of the spray gun to generate a spray pattern test see 4 Connecting supply lines a...

Страница 15: ...he material needle component A Note The setting dimension of the material needle is 117 mm from the tip of the needle to the needle chuck 1 3 2 5 3 Replacing the valve component B 5 4 Replacing a leak...

Страница 16: ...ray gun can be damaged and spraying results degraded Use only those cleaning materials for cleaning the spray gun which have been prescribed by the manufacturer of the spraying material and which do n...

Страница 17: ...terial see operating instructions of system manufacturer Tighten Gun keeps blo wing in off position Valve spring Item 6 3 or Valve shaft Item 6 2 dama ged Replace 8 Disposal Waste spraying media and w...

Страница 18: ...gences de s curit et d hygi ne fondamentales s y rapportant En cas de modification de l appareil r alis e sans notre accord ou en cas d utilisation non conforme la pr sente d claration perd sa validit...

Страница 19: ...11 815 67 000 1 V 11 815 67 000 14 Vis sans t te partiellement filet e 1 V 11 815 63 000 1 V 11 815 63 000 15 Contre vis de la g chette 1 V 10 301 09 000 1 V 10 301 09 000 16 Raccord enfichable 1 V 66...

Страница 20: ...liquide la pulv risation de produits inflammables 2 Caract ristiques techniques Le G9 2K est un mod le de pistolet pulv risateur pour l application de colles dispersion deux composants Le transport d...

Страница 21: ...ont pour l entretien ou la r paration L essai de pulv risation peut tre r alis sur une pi ce chantillon une t le du car ton ou du papier 1 Mettez le pistolet pulv risateur en service afin de faire un...

Страница 22: ...le non tanche composant A 5 1 Remplacement de la buse de produit et de la t te air 5 2 Remplacement de l aiguille de produit composant A Remarque La dimension r gl e de l aiguille de produit est de 11...

Страница 23: ...r cision du pistolet pulv risateur pourraient tre endommag es et emp cher d obtenir un bon r sultat de pulv risation Pour le nettoyage du pistolet pulv risateur n utilisez que des produits de nettoyag...

Страница 24: ...esser r e ou endommag e Rajouter du produit voir manuel d utilisation du fabri cant de l installation Serrer ou remplacer Le pistolet souff le lorsqu il est au repos Ressort de valve pos 6 3 ou tige d...

Страница 25: ...tinuaci n cumple los requisitos b sicos pertinentes sobre segu ridad y salud Esta declaraci n pierde su validez si se realiza cualquier modificaci n en el aparato que no haya sido acordada con nosotro...

Страница 26: ...5 50 103 13 Gatillo 1 V 11 815 67 000 1 V 11 815 67 000 14 Tornillo de v stago 1 V 11 815 63 000 1 V 11 815 63 000 15 Tornillo del gatillo 1 V 10 301 09 000 1 V 10 301 09 000 16 Racor de empalme 1 V 6...

Страница 27: ...l quido La pulverizaci n de materiales inflamables 2 Descripci n t cnica El G9 2K es un modelo de pistolas de pulverizaci n para la aplicaci n de adhesivos en dispersi n de dos componentes El bombeo...

Страница 28: ...La prueba gr fica de la pulverizaci n se puede efectuar sobre una pieza de prueba una chapa cart n o papel 1 Ponga a funcionar la pistola de pulverizaci n para crear una prueba gr fica de la pulveriza...

Страница 29: ...anca componente A 5 1 Cambiar la tobera de material y el cabezal de aire 5 2 Cambiar la aguja de material componente A Aviso El tama o de ajuste de la aguja de material es de 117 mm desde la punta de...

Страница 30: ...ni puntiagudos De lo contrario podr an da arse las piezas de precisi n de la pistola de pulverizaci n y empeorar el result ado de pulverizado Para limpiar la pistola de pulverizaci n utilice nicament...

Страница 31: ...ante del equipo apretar o reemplazar La pistola burbu jea en posici n de reposo Resorte de v lvula pos 6 3 o v stago de v lvula pos 6 2 da ado reemplazar 8 Eliminaci n de desechos Los productos de pul...

Страница 32: ...nia odpowiednie podstawowe wymogi w zakresie bezpiecze stwa i ochrony zdrowia W przypadku dokonania zmian w urz dzeniu bez porozumienia z producentem lub u ytkowania urz dzenia niezgodnie z jego przez...

Страница 33: ...50 103 13 Spust kompl 1 V 11 815 67 000 1 V 11 815 67 000 14 ruba bez ba 1 V 11 815 63 000 1 V 11 815 63 000 15 ruba spustu 1 V 10 301 09 000 1 V 10 301 09 000 16 Z czka wtykowa gwintowana 1 V 66 100...

Страница 34: ...materia u w stron os b lub zwierz t rozpryskiwanie ciek ego azotu rozpryskiwanie palnych materia w 2 Opis techniczny Model SIMALFA G9 2K pistolet natryskowy przeznaczony do natrysku dwusk adni kowych...

Страница 35: ...cz ci w celu konserwacji lub naprawy Natrysk pr bny mo na przeprowadzi na przedmiocie pr bnym tekturze lub papier ze 1 Uruchomi pistolet natryskowy i wykona pr b natrysku patrz punkt 4 Pod czenie prz...

Страница 36: ...na iglicy materia owej sk adnik A Wskaz wka Wymiar nastawczy iglicy materia owej wynosi 117 mm mierz c od czubka iglicy do nakr tki iglicy 1 3 2 5 3 Wymiana zaworu sk adnika B 5 4 Wymiana wadliwego us...

Страница 37: ...szy jako natrysku Do czyszczenia pistoletu natryskowego stosowa wy cznie rodki czyszcz ce zale cane przez producenta materia u natryskowego i niezawieraj ce nast puj cych sk adnik w w glowodory haloge...

Страница 38: ...ducenta instalacji Dokr ci lub wymieni Pistolet nie zamyka w trybie spoczynku Uszkodzona spr yna zaworu poz 6 3 lub trzonek zaworu poz 6 2 Wymieni 8 Usuwanie zu ytych materia w Materia y natryskowe ja...

Страница 39: ...ALFA Klebstoffe AG Vor Eiche 10 CH 8197 Rafz Switzerland www simalfa ch www alfa swiss...