![SIM Tech SIM5360A Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/sim-tech/sim5360a/sim5360a_hardware-design_1274309046.webp)
Smart Machine Smart Decision
SIM5360_Hardware Design_V1.06
2016-11-17
46
Figure 30: EXT CODEC to MODULE timing
Figure 31: MODULE to EXT CODEC timing
Table 30: Timing parameters
Parameter
Description
Min
Typ
Max
Unit
T(auxsync)
AUX_PCM_SYNC cycle time
–
125
-
μs
T(auxsynch)
AUX_PCM_SYNC high time
62.4
62.5
-
μs
T(auxsyncl)
AUX_PCM_SYNC low time
62.4
62.5
-
μs
T(auxclk)*
AUX_PCM_CLK cycle time
-
7.8
–
μs
T(auxclkh)
AUX_PCM_CLK high time
3.8
3.9
–
μs
T(auxclkl)
AUX_PCM_CLK low time
3.8
3.9
–
μs
T(suauxsync)
AUX_PCM_SYNC setup time high before
falling edge of PCM_CLK
1.95
–
–
μs
T(hauxsync)
AUX_PCM SYNC hold time after falling edge
of PCM_CLK
1.95
–
–
μs
SIMCOM
CONFIDENTIAL
FILE