SIM5360_Hardware Design_V1.06
2016-11-17
24
3.1.3
RTC Backup
The module uses RTC (Real Time Clock) to update and maintain inherent time at no VBAT power supply
status. The RTC power supply of module can be provided by an external capacitor or a battery
(non-chargeable or rechargeable) through the VRTC. The following figures show various reference circuits
for RTC back up. The discharge current is less than 10uA.
External capacitor backup
RTC
Core
Module
VRTC
Large-capacitance
Capacitor
Figure 11: RTC supply from capacitor
Non-chargeable battery backup
RTC
Core
Module
VRTC
Non-chargeable
Backup Battery
Figure 12: RTC supply from non-chargeable battery
Rechargeable battery backup
RTC
Core
Module
VRTC
Rechargeable
Backup Battery
Figure 13: RTC supply from rechargeable battery
SIMCOM
CONFIDENTIAL
FILE