It is understood that only burners operating with G20 gas should be subjected to the
above mentioned adjustments. The screw must be fully locked when the burners
operate with G30 or G31.
REPLACING
THE
INJECTORS
The burners can be adapted to different types of gas by mounting injectors suited to the
type of gas in question. To do this, first remove the burner tops using a wrench "B". Now
unscrew injector "A" (see fig. 13) and fit a injector corresponding to the utilized type of
gas in its place.
It is advisable to strongly tighten the injector in place.
After the injectors have been replaced, the burners must be regulated as explained in
paragraphs 9. The technician must reset any seals on the regulating or pre
-
regulating
devices and affix the label corresponding to the new gas regulation on the appliance
instead of the already existing one. This label is supplied in the packet containing the
spare injectors. The envelope with the injectors and the labels can be included in the kit,
or at disposal to the authorized customer Service Centre.