5.Installion
To insert the lamp MSR 250/2 loosen the lamp cover at the rear of head (see the
drawings ) by remowing the 3 fastening screws which are marked "X,Y,Z" . Carefully pull
out the cover with the lamp socket assembly.If changing the lamp, remove the old lamp
from the socket. Insert the lamp to the socket.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the
device is not de-signed for.Damages caused by non-observance are not subject to warranty.
Please follow the lamp manufacturer notes!Do not touch the glass-bulb with bare hands
during the installation! Make sure that thelamp is installed tightly into the lampholder
system.
Reclose the lamp cover and tighten the 3 screws.
.Lamp assembly:
5.1
Fitting the lamp
3 phillips screws "X,Y,Z"
3 adjustment screws "A,B,C"
5.2 Lamp adjust
The WASH 250 lampholder is aligned at
the factory. Due to differences between
lamps , fine adjustment may improve light
performance.Strike the lamp,open the shutter
and the iris,set the dimmer intensity onto
100% and focus the light on a flatsurface
(wall).Center a hot-spot(the brightest par t of
the image) by using the 3 adjustment screws
"A,B,C".Turn one screw after another a
quarter-turn clokwise(counter-clokwise. If
you cannot detect the hot-spot,adjust the
lamp until the light is evenly distributed.
-4-
Lamp
assembly