New Product Warranty 
 

 
 

Silvan Australia Pty. Ltd. builds equipment to a high level of specification using components from 
quality suppliers. The following information is provided to assist you with any repairs required within 
the warranty period. All warranty repairs on Silvan products are carried out by Silvan dealers. If any 
warranty repairs are required on Silvan products, it is recommended that the product be returned to 
the place of purchase. It is good practice to keep a record of equipment maintenance both during and 
after the warranty period. 
The warranty policy below explains the extent and limitations of your Warranty coverage on 
Silvan Products.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

This warranty is the only warranty applicable to Silvan new products ('Products') and, to the 
maximum extent permitted by law, is expressly in lieu of any other conditions or warranties 
expressed or implied in relation to the Products.   
Subject only to legislative obligations to the contrary, Silvan shall not be liable for incidental or 
consequential damage resulting from ownership or use of a Product. Silvan does not authorize 
any person to create for it any other obligation or liability in connection with these products. 
 
Silvan warrants its authorised Dealer, who in turn warrants the original purchaser (owner) of each 
new Silvan product that it will repair or replace the product, or, pay the cost of repair or 
replacement, as determined by Silvan without charge for labour or any defective or malfunctioning 
parts in accordance with the warranty limitations and adjustment schedule below. 
 
The warranty period begins on the date the product is delivered to the first retail purchaser for a 
period of 12 months 
 
This Warranty Covers: Only conditions resulting directly from defects in workmanship or material 
under normal use and service. 
 

Warranty Exclusions: The Warranty does not cover: 

 

Conditions resulting from misuse, use of incompatible chemicals, exceeding machine 
specifications including overloading, impact damage, negligence, accidental damage or 
failure to perform recommended maintenance services. 

 

Any product which has been repaired by other than an authorised Silvan service outlet in 
a way which, in the sole and absolute judgement of Silvan, adversely affect its 
performance or reliability. 

 

The replacement of maintenance items such as diaphragms, batteries, V belts and ground 
engaging components, etc. 

 

Loss of time, inconvenience, loss of use of the product, liability to third parties or any other 
consequential damages. 

 

Incidental costs associated with a warranty repair including any travel costs, out of hour’s 
labour charges, cleaning costs, transportation costs, freight costs or any communication 
costs. 

 

The repair of a defective product qualifying under this warranty will be performed by any 
authorised Silvan service outlet within a reasonable time following the delivery of the 
product, at the cost of the owner, to the service outlet’s place of business.  The product 
will be repaired or replaced, using new parts supplied by Silvan.  Silvan, at its absolute 
discretion, may choose to pay the cost of replacement or repair of the product. 

 
The owner is responsible for the performance of regular maintenance services as specified in the 
Owner/Operator Manual applicable to the product. Failure to carry out regular maintenance may 
invalidate warranty. 

 

Содержание Oktopus 500L

Страница 1: ...Operator s Manual MANSLV 1 Rev C October 2018 500 Litre Linkage Oktopus Sprayer...

Страница 2: ...13 14 Lubrication and Maintenance Daily Weekly Monthly and Annual Maintenance 15 Trouble Shooting 16 Trouble Shooting 15 Lubrication and Maintenance 16 Warranty Certificate 19 YOUR SPRAYER DETAILS Rec...

Страница 3: ...ranty period begins on the date the product is delivered to the first retail purchaser for a period of 12 months This Warranty Covers Only conditions resulting directly from defects in workmanship or...

Страница 4: ...nsion chamber and protective mesh screen Two speed oil bath gearbox with neutral position Max Speed 540 PTO rpm 2 700 rpm Air speed 450 dia fan 80 m sec Capacity 450 dia fan 14 000 m3 hr PTO Drive Qua...

Страница 5: ...and power requirement of the sprayer Refer to the tractor operator s manual for safe working loads and relevant tractor safety instructions Exercise extreme care when operating in hilly or uneven ter...

Страница 6: ...ead and follow the information on all safety decals before operating the sprayer Failure to comply with these warnings could result in serious injury or death Safety decals should be kept clean and le...

Страница 7: ...rding of the safety decals shown on the previous pages is given below Before operating the sprayer read all safety warning decals Failure to comply with these warnings could result in serious injury o...

Страница 8: ...ayer it is the selling dealer s responsibility to install and set the PTO shaft to the correct length The following information is provided for reference Set the linkage height so the ends of the two...

Страница 9: ...le diffuser nozzle Width Loosen the U bolt 1 and slide the inside RHS 2 to the desired width Re tighten the U bolt Height Loosen the 8mm bolt 3 and slide the tube outlet mount 4 to the desired height...

Страница 10: ...centrifugal clutch which protects the gearbox and driveline if the PTO is engaged rapidly The sprayer should always be operated at 540 PTO rpm to ensure correct operation of the centrifugal clutch and...

Страница 11: ...t for the remaining sections The sprayer is then adjusted correctly Adding Chemicals Chemicals are added to the tank through the top lid opening Take care to avoid the spillage of chemicals or mixed s...

Страница 12: ...laced in the standard positions If their position should be changed make sure that the jet is spraying into the air stream and not fouling on the diffuser as shown below HCC Hollow Cone Ceramic Jets H...

Страница 13: ...2 Total Output Required Calculate the total spray output required in litres per minute l min using the following formula Check that the calculated output does not exceed the rated capacity of the pump...

Страница 14: ...2 Orange at 10 11 Bar pressure will give the desired output An alternative would be to use HCC025 Red at 7 Bar pressure to give the equivalent output 2 Orchard Fruits Application rate 1200 l ha Travel...

Страница 15: ...0 x 5 x 3 600 10 l min Date of Test _______________ Application Rate _______________ litres ha Speed of Travel _______________ km hr Row Spacing _______________ metres No of nozzles _________ Output p...

Страница 16: ...run clean water through the pump and lines to purge them of chemicals Rinse out the tank to remove powdered material Never leave chemicals in the tank that may settle to the bottom harden and break in...

Страница 17: ...f the pump Air trapped in filter or suction lines Pump does not prime No liquid in tank or not covering suction inlet Suction filter blocked Suction filter stop valve closed Suction filter bowl loose...

Страница 18: ...1 SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 68 Atlantic Drive Keysborough VIC 3173 Australia Telephone 1300 745 826 Facsimilie 1800 745 826 www silvan com au...

Отзывы: