Calibration

 

 

3. Berries

 

 

Application rate  

400 l/ha 

 

Travel speed 

 

5 km/hr 

 

Row width 

 

3 m 

 

Spraying pressure 

13 Bar 

 
 
 
 
 
 
 
If using 8 nozzles (4/side) with two turned off due to a smaller canopy then each nozzle needs 
to deliver 1.25 l/min. From the HCC nozzle chart HCC015 (Yellow) at 13 Bar pressure will give 
the desired output. An alternative nozzle would be the HCC02 at approximately 7 Bar to give an 
equivalent output. 
 

Calibration Worksheets 
 

The worksheets below can be used to record the results of calibration tests on your sprayer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

 

 

     Total Application Rate (l/min)  =  

  Application rate (l/ha) x Speed (km/hr) x Row width (m)  

                                       

 

 

 

 

 

 600  

 

400 x 5 x 3 
          600

 

= 10

 l/min 

       

Date of Test: _______________ 

 
Application Rate: _______________  litres/ha 

 
 Speed of Travel: _______________  km/hr 

 
     Row Spacing: _______________  metres 
 

 
 
 
 
 
 

 
 
 
     No. of nozzles : _________                    

       

Output per nozzle : _________ litres/min 
 
 Nozzle Selection : __________ 
 
  Pressure Setting: __________ Bar 
 
 Measured Output: _________ litres/min 
  (from test run) 

 
 

Output (l/min)

  = 

Application Rate x Speed x Row Width 

                            600

 

                           x           x  

                            600

 

=           
litres/min 

       Date of Test: _______________ 

 
Application Rate: _______________  litres/ha 

 
 Speed of Travel: _______________  km/hr 

 
     Row Spacing: _______________  metres 
 

 
 
 
 
 
 

 
 
 
     No. of nozzles : _________                    

       

Output per nozzle : _________ litres/min 

 

 Nozzle Selection : __________ 
 
  Pressure Setting: __________ Bar 
 
 Measured Output: _________ litres/min 
  (from test run) 

 
 

Output (l/min)

  = 

Application Rate x Speed x Row Width 

                            600

 

                           x           x  

                            600

 

=           
litres/min 

Содержание Oktopus 500L

Страница 1: ...Operator s Manual MANSLV 1 Rev C October 2018 500 Litre Linkage Oktopus Sprayer...

Страница 2: ...13 14 Lubrication and Maintenance Daily Weekly Monthly and Annual Maintenance 15 Trouble Shooting 16 Trouble Shooting 15 Lubrication and Maintenance 16 Warranty Certificate 19 YOUR SPRAYER DETAILS Rec...

Страница 3: ...ranty period begins on the date the product is delivered to the first retail purchaser for a period of 12 months This Warranty Covers Only conditions resulting directly from defects in workmanship or...

Страница 4: ...nsion chamber and protective mesh screen Two speed oil bath gearbox with neutral position Max Speed 540 PTO rpm 2 700 rpm Air speed 450 dia fan 80 m sec Capacity 450 dia fan 14 000 m3 hr PTO Drive Qua...

Страница 5: ...and power requirement of the sprayer Refer to the tractor operator s manual for safe working loads and relevant tractor safety instructions Exercise extreme care when operating in hilly or uneven ter...

Страница 6: ...ead and follow the information on all safety decals before operating the sprayer Failure to comply with these warnings could result in serious injury or death Safety decals should be kept clean and le...

Страница 7: ...rding of the safety decals shown on the previous pages is given below Before operating the sprayer read all safety warning decals Failure to comply with these warnings could result in serious injury o...

Страница 8: ...ayer it is the selling dealer s responsibility to install and set the PTO shaft to the correct length The following information is provided for reference Set the linkage height so the ends of the two...

Страница 9: ...le diffuser nozzle Width Loosen the U bolt 1 and slide the inside RHS 2 to the desired width Re tighten the U bolt Height Loosen the 8mm bolt 3 and slide the tube outlet mount 4 to the desired height...

Страница 10: ...centrifugal clutch which protects the gearbox and driveline if the PTO is engaged rapidly The sprayer should always be operated at 540 PTO rpm to ensure correct operation of the centrifugal clutch and...

Страница 11: ...t for the remaining sections The sprayer is then adjusted correctly Adding Chemicals Chemicals are added to the tank through the top lid opening Take care to avoid the spillage of chemicals or mixed s...

Страница 12: ...laced in the standard positions If their position should be changed make sure that the jet is spraying into the air stream and not fouling on the diffuser as shown below HCC Hollow Cone Ceramic Jets H...

Страница 13: ...2 Total Output Required Calculate the total spray output required in litres per minute l min using the following formula Check that the calculated output does not exceed the rated capacity of the pump...

Страница 14: ...2 Orange at 10 11 Bar pressure will give the desired output An alternative would be to use HCC025 Red at 7 Bar pressure to give the equivalent output 2 Orchard Fruits Application rate 1200 l ha Travel...

Страница 15: ...0 x 5 x 3 600 10 l min Date of Test _______________ Application Rate _______________ litres ha Speed of Travel _______________ km hr Row Spacing _______________ metres No of nozzles _________ Output p...

Страница 16: ...run clean water through the pump and lines to purge them of chemicals Rinse out the tank to remove powdered material Never leave chemicals in the tank that may settle to the bottom harden and break in...

Страница 17: ...f the pump Air trapped in filter or suction lines Pump does not prime No liquid in tank or not covering suction inlet Suction filter blocked Suction filter stop valve closed Suction filter bowl loose...

Страница 18: ...1 SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 68 Atlantic Drive Keysborough VIC 3173 Australia Telephone 1300 745 826 Facsimilie 1800 745 826 www silvan com au...

Отзывы: