background image

 

This  pump  has  been  designed  and 
constructed  solely  to  pump  agricultural 
liquid  chemicals,  normally  used  for  pest, 
weed and fungus control. 

Must Not Be Used To Pump: 

· Liquids with a density and viscosity greater 
than water. 
· Chemical products if the compatibility with 
the materials of the pump is not known. 
· Sea water or other salty concentrations. 
· Water with a temperature above 40°C and 
less than 5°C. 
· Any type of varnish. 
· Solvents  and  thinners  for  any  type  of 
varnish. 
· Any type of fuel or lubricant. 
· Liquids containing granules or floating solid 
parts. 
· Chlorine. 
· For  special  liquids  please  contact  Silvan 
service department. 

Pre-Operational Checks: 

1.

 

Check  the  oil  level  while  the  pump  is 
standing still and sitting horizontally. The 
oil must reach the level indicated on the 
sight  glass  (fig  1).  Top  up  with  SAE 
20W/50 oil if necessary. 

    

 

Figure 1                    Figure 2

 

2.

 

Adjust  the  air  pressure  in  the  pressure 
accumulator  if  fitted  (fig  2)  in 
accordance with the operating pressure 
used to spray. Adjust according to Table 
A. The pressure can be measured using a 
car tyre pressure gauge. 

TABLE A 

Spraying 
Pressure 

Bar 

 5 

 10 

10 

 20 

20 

 50 

Psi 

29 

 73 

73 

 145 

145 

 290 

290 

 725 

Surge 

Air 

Pressure 

Bar 

 5 

 7 

Psi 

29 

29 

 73 

73 

 102 

102 

 

Start Up:

 

1.  Ensure  the  control  valve  is  in  the  bypass 

position and any taps not being used are 
in the closed position. Turning the bypass 
lever in the clockwise direction will place 
it  in  the  bypass  position.  Repeat  this 
procedure each time the pump has been 
emptied of liquid i.e. Run dry. 

2. Bring the pump to operating speed.  

3. Switch off the bypass and bring the pump 

to operating pressure for the application 
using the pressure regulator. 

4. Check the oil level during the first hours of 

operation and top up if necessary. 

Shutdown: 

Flush  the  pump  after  use  by  running  clean 
water for a few minutes 

If there is a risk of freezing run the pump dry 
for a few minutes to remove all liquid from 
the pump 

Component Identification: 

Refer to the diagram for the position of the 
various components relating to your pump. 

 1.  Oil Reservoir 
 2.  Pressure Accumulator 
 3.  Pump Head 
 4.  Inlet Hose Barb 
 5.  Inlet Valve Cap 
 6.  Pump Crankcase 
 7.  Retaining Clamp 
 8.  By-pass Lever 
 9.  Pressure Adjusting Knob 
10.  Outlet 

 

 

 

Operation (Motorised Version) 

 

 

Содержание LT30-34

Страница 1: ...PRAYERS 300L LT30 S8 LT30 34 VICTORIA HEAD OFFICE Telephone 61 03 9215 2700 Fax 61 03 9215 2701 www silvan com au NEW ZEALAND Hamilton New Zealand Telephone 64 07 8496 033 Fax 64 07 8496070 www silvan...

Страница 2: ...reserves the right to make changes at any time without notice YOUR SPRAYER DETAILS Record the details of your Lightfoot Sprayer here for future reference when discussing service with your Silvan deal...

Страница 3: ...ot cover Conditions resulting from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommen...

Страница 4: ...tors and associated personnel are familiar with the legal regulations and codes of practice that apply to the safe use storage and disposal of spray chemicals Warning Before carrying out maintenance w...

Страница 5: ...ressure switch to cut the power to the motor When using the 12 volt spray unit in spot spraying applications the pressure switch can act to function as an automatic on demand switch stopping the pump...

Страница 6: ...ower The switch also allows the pump to be shut down when the tank is empty preventing overheating and damage to the pump A 30 amp fuse is fitted to the control box to prevent any potential damage to...

Страница 7: ...l to the sprayer 2 Check the filter is clean and undamaged see Maintenance section 3 Fill the tank with clean water 4 Check all pipes hoses hose clamps and connections for leaks or damage 5 Switch the...

Страница 8: ...praying is completed drain unused chemicals from the tank Rinse the tank with clean water then operate the sprayer with clean water in the tank to clean out the pump hose and spray lance Do not leave...

Страница 9: ...re can be measured using a car tyre pressure gauge TABLE A Spraying Pressure Bar 2 5 5 10 10 20 20 50 Psi 29 73 73 145 145 290 290 725 Surge Air Pressure Bar 2 2 5 5 7 7 Psi 29 29 73 73 102 102 Start...

Страница 10: ...ol is recirculated to maintain agitation within the tank System pressure is regulated by turning the knob B and observing the reading on the pressure gauge Turning the knob clockwise increases the pre...

Страница 11: ...an external suction filter Unscrew the cap on the filter housing in order to remove the filter Clean the filter with clean water and a bristle brush do not use a wire brush or sharp object as this may...

Страница 12: ...e that the tyres are correctly inflated Measure and mark 100 metres Approach the starting mark at the required spraying speed and accurately measure the time in seconds to reach the finishing mark The...

Страница 13: ...ray Width Breakback Facility Part Number Compatibility LT30 S8 2 1 05 meters 2 meters NO L99 09 YES 3 2 05 meters 3 meters NO L99 08 YES 4 3 meters 4 meters NO RP1 10 YES Note Indicates a Pressure Reg...

Отзывы: