Two Outlet Ball Type Control Valve:
The selection of either the bypass or pressure mode is controlled by the
rotary lever “A”
- refer to
diagram. Moving the lever clockwise through its full travel selects bypass, which recirculates the full
flow of fluid from the pump to the tank via the agitator line.
Moving the lever its full travel anti-clockwise directs pressurised fluid to the boom, and only the
overflow from the pressure control is recirculated to maintain agitation within the tank.
System pressure is regulated by turning the knob “B” and observ
ing the reading on the pressure
gauge. Turning the knob clockwise increases the pressure and turning anti-clockwise decreases
pressure.
Fluid is directed to the boom lines by the outlet
valves “C”. The outlet valves may be operated
individually and are open when the lever is in line with the direction of flow and closed when across
the direction of flow.
If you wish to stop spraying but keep the motor
running, close the outlet valves “C” and move the
bypass lever “A” to bypass mode
.
Operation (Motorised Version, cont.)